60
en | Error Codes
MIC IP starlight 7000i
2019-11 | 2.1 |
Installation Manual
Bosch Security Systems
Status
Code
Description
Recommended action
(to be completed by a qualified Service
Technician)
11
Wiper operation has been halted
because of an obstruction.
1. Remove any obvious materials that are
obstructing operation of the wiper.
2. If the obstruction is from ice buildup,
review the diagnostic log of the camera
(accessible from the
Service
menu) for errors
related to operation of the internal heaters
(and the window defrosters, for MIC IP fusion
9000i). If possible, tilt the camera so that the
front faceplate is pointed straight up. (In this
position, heat generated by the camera will
help to melt ice buildup from its front
faceplate area.)
3. If the obstruction is from extreme ice
buildup, temporarily avoid operating the
wiper until internal heaters, combined with a
rise in ambient temperature, melt the ice
buildup.
12
Left and Right Pan Limits have been
set too close to each other.
Re-configure one camera stop limit or the
other to increase the distance between limit
stops to at least 10° apart.
13**
Autofocus has been turned off
because of excessive focus activity.
1. If practical, increase lighting in the scene
so that the focus function stops “hunting.”
2. Use focus in manual mode or One-Push
mode.
14**
Washer operation was attempted
without washer pre-position being
stored.
Configure the washer pre-position. If
necessary, refer to the subchapter “Using the
Wiper/Washer (Bosch AUX/Pre-position
Commands)” in the User Manual for details
on configuring washer functions.
15
Attempt was made to move to a pre-
position that is mapped to an
alternate function, so it is no longer
associated with a location.
1. Select/configure a different pre-position
number for the desired location.
2. Re-configure the pre-position assignment
so that this number is no longer associated
with an alternate function. Refer to the
subchapter “
Pre-position mapping
” in the
User Manual for details on re-mapping pre-
positions.
16**
Motorized zoom function is
programmed to operate at a high
usage level in the Playback Tour.
This high rate of usage could result
in premature wear of the zoom
motor.
Re-configure the camera to decrease the
zoom activity to less than 30% during
recording.