![Bosch MIC IP 7000 HD Series Tech Note Download Page 11](http://html.mh-extra.com/html/bosch/mic-ip-7000-hd-series/mic-ip-7000-hd-series_tech-note_40672011.webp)
Configuration of MIC IP 7000 HD – VIDEOJET decoder 3000 – for integration with analog CCTV
|
11
/18
Bosch Security Systems
Version 1.3 | September 2015
4.3
MIC IP 7000 HD Configuration
There are only two required setting changes needed to configure the MIC IP 7000 HD to make it
compatible with an analog CCTV system. These are described below.
A temporary network connection to access the camera’s web browser or use of the Bosch Configu-
ration Manager software is required in order to make these changes. Please refer to the MIC
Operating manual which can be found at the link in section 1 for complete information on how to
connect the MIC camera up to an IP network. Note the factory default IP address of the camera is
192.168.0.1.
4.3.1 Select the Encoder Streams menu from the menu options on the left pane.
-
Set the Stream 2 Property to H.264 MP D1 4:3 (cropped).
-
Set the Non-recording profile for Stream 2 to 4: SD Image Optimized. Click the Set button.
Figure 8: Encoder streams selection menu