background image

EN

| 8

Bosch Security Systems | 7 April 2004

LTC 5104, LTC 5108 Series 

Instruction Manual

Unpacking

1

UNPACKING

Unpack carefully. This is electronic equipment and
should be handled with care.

Check for the following items:

Verify the unit model number.

One (1) cable assembly with 15-pin connector.

If an item appears to have been damaged in shipment,
replace it properly in its carton and notify the shipper.
If any items are missing, notify your Bosch Security
Systems, Inc. Sales Representative or Customer
Service.

The shipping carton is the safest container in which the
unit may be transported. Save it for possible future use.

2

SERVICE

If the unit ever needs repair service, the customer
should contact the nearest Bosch Security Systems, Inc.
Service Center for authorization to return and shipping
instructions.

Service Centers

USA: Phone:

800-366-2283 or 717-735-6638

fax:

800-366-1329 or 717-735-6639

CCTV Spare Parts

Phone:

800-894-5215 or 408-956-3853 or 3854

fax:

408-957-3198

e-Mail:

[email protected]

Canada:

514-738-2434

Europe, Middle East & Asia Pacific Region:

32-1-440-0711

For additional information, see
www.boschsecuritysystems.com.

3

DESCRIPTION

The LTC 5104 Series and LTC 5108 Series are
automatic sequential video switchers. The LTC 5104
Series have 4-camera inputs and 1-monitor output; the
LTC 5108 Series have 8-camera inputs and 2-monitor
outputs.

4

INSTALLATION

4.1

Power

Model

Rated

Voltage Power 

at

No.

1

Voltage

Range Rated  Voltage

LTC 5104/60

120 VAC, 50/60 Hz

105 to 130

4 W

LTC 5104/50

220-240 VAC, 50/60 Hz

198 to 264

4 W

LTC 5108/60

120 VAC, 50/60 Hz

105 to 130

4 W

LTC 5108/50

220-240 VAC, 50/60 Hz

198 to 264

4 W

1

Models shown are for English on-screen menu model. The model

number and operating voltage are shown on the bottom of the unit.
These units are supplied with grounded power cords; grounding must
not be defeated.

4.2

Mounting

These switchers are half rack units and are supplied as
desk top units. For rack mounting, the LTC 9101/00
rack-mount kit is available.

4.3

Video Inputs and Looping Outputs

For each of the 4 or 8 channels, there are two BNC
connectors on the rear panel. One of these connectors
is to be used as a video input while the other connector
may be used as a looping output. It does not matter
which connector is used as the input and which is used
as the looping output. Each pair of BNCs provides an
automatic termination function that applies a 75 

load

to the incoming video signal when the cable is
connected to either jack. When "loop-through"
operation is desired, the second cable connection
automatically unterminates the input providing the
required high impedance for "loop-through" operation.
The jacks act as automatic switches. The looping video
outputs are provided to supply video to other video
equipment. When looping, the last piece of equipment
on the video line should be terminated.

4.4

Monitor Output

The monitor outputs are designed for a 75 

load.

Therefore, when looping the monitor output cable
through multiple monitors or their accessories, ensure
their terminations are set to Hi-Z. Only the last unit on
the line should have its termination set to 75 

.

LTC 5104 Series: A single monitor output permits
switched camera video through this connection.

LTC 5108 Series: These switchers may be used with
one or two monitors, depending on system
requirements. See 

Operating Mode

section and 

Typical

Installation

illustration.

Summary of Contents for LTC 5104 Series

Page 1: ...Instruction Manual EN 4 and 8 Position Premium Sequential Switchers LTC 5104 LTC 5108 Series ...

Page 2: ...rical shock or other hazards 9 Safety Check Upon completion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact your dealer or local power company For units intended to operate from ...

Page 3: ...s only refer to the National Electrical Code Article 820 regarding installation of CATV systems For Rack Mount Product 1 Ventilation This unit should not be placed in a built in installation or rack unless proper ventilation is provided or the manufacturer s instructions have been adhered to The equipment must not exceed its maximum operating temperature requirements 2 Mechanical Loading Mounting ...

Page 4: ...ce and 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules and ICES 003 of Industry Canada These limits are designed to provide reasonable protection against harmful interference when the equipment is ope...

Page 5: ...r Dokumentation hinweisen die dem Gerät beiliegt Precauciones de Seguridad Atención La instalación debe realizarla personal cualificado en cumplimiento estricto del código eléctrico nacional en el caso de los EE UU o de los códigos locales aplicables Para Desconectar la Alimentación Unidades no equipadas con interruptores ON OFF son alimentadas cuando el cable de alimentación es conectado a la cor...

Page 6: ...doeld om de gebruiker te waarschuwen voor de aanwezigheid van belangrijke bedienings en onderhouds service instructies in de documentatie die met het product zijn meegeleverd Sicurezza Precauzione affidare l installazione al solo personale qualificato e nel rispetto del Codice elettrico nazionale USA o dei codici locali pertinenti Scollegamento dell alimentazione Gli apparecchi con o senza commuta...

Page 7: ...ies Only 10 4 10 Alarm Reset Mode 10 4 11 Alarm Capture 11 4 12 Alarm Capture Time 11 4 13 Alarm Dwell Time 11 4 14 Alarm Contact Closures 11 4 15 Status Line 12 4 16 Screen Display Brightness and Background 12 4 17 Screen Display Position 12 4 18 Programming Camera Titles 12 5 OPERATION 13 5 1 DWELL Key 13 5 2 SKIP clr Key 13 5 3 ALARM Key 13 5 4 RUN next Key 13 5 5 Numeric Channel Keys 13 6 ILLU...

Page 8: ...8 50 220 240 VAC 50 60 Hz 198 to 264 4 W 1 Models shown are for English on screen menu model The model number and operating voltage are shown on the bottom of the unit These units are supplied with grounded power cords grounding must not be defeated 4 2 Mounting These switchers are half rack units and are supplied as desk top units For rack mounting the LTC 9101 00 rack mount kit is available 4 3 ...

Page 9: ...ive false inputs or damage the switcher 4 6 Programming System Setup Configuration options are provided through on screen menus These menus are accessed by using the DWELL key With video present on the monitor a momentary press and release of the DWELL key will gain easy access to the Dwell Time Menu see SCREEN 1 Screen 1 The remaining configuration menus 8 for the LTC 5104 Series and 9 for the LT...

Page 10: ...mera input Since no dwell menu can be displayed if there is no video to that input it is recommended to skip all camera inputs without video before attempting to set individual dwell times Once in Individual mode the Dwell Time menu must be exited and re entered if All Cameras mode is desired SKIP clr decreases displayed dwell time and ALARM increases dwell time The default is All Cameras with a d...

Page 11: ...he minimum length of time that the alarm call up will be held once its contact closure is detected During multiple alarms the Capture Time expires only while the alarm is being displayed Use SKIP clr to decrease time and ALARM to increase time Alarm capture time can be set from 1 second to 63 seconds The default time is 14 seconds Screen 6 4 13 Alarm Dwell Time The Alarm Dwell Time determines how ...

Page 12: ... or block format Use SKIP clr to make the display lighter and ALARM darkens the display When the end of the brightness range has been reached the background format will toggle The default background is silhouette Screen 10 4 17 Screen Display Position The display may be positioned both horizontally and vertically see SCREEN 11 The numeric 1 key is used to move the display up 2 to move down 3 to mo...

Page 13: ...the notation MA Monitor Armed appears on the status line appears only on Monitor B for the LTC 5108 Series The switcher responds to all incoming alarms During the alarm period the word ALARM flashes on the status line and the alarm LED flashes When the Alarm is off The alarm indicator LED is not lit and no MA notation is present on the status line When the alarm function is off the switcher will n...

Page 14: ... 1 LTC 5104 Series 1 6 11 2 7 12 3 8 13 4 9 14 5 10 15 Pin Function 1 Ground 2 Alarm 3 3 NC 4 Reserved 5 Reserved 6 Alarm 1 7 Alarm 4 8 NC 9 Alarm Relay NO 10 Reserved 11 Alarm 2 12 NC 13 NC 14 Alarm Relay NO 15 Reserved NC No Connection NO Normally Open Screen 13 Front Panel and Back Panel Screen 14 Connector Diagram ...

Page 15: ... Series 1 6 11 2 7 12 3 8 13 4 9 14 5 10 15 Screen 16 Connector Diagram Pin Function 1 Ground 2 Alarm 3 3 Alarm 6 4 Monitor Strobe 1 5 Data 0 6 Alarm 1 7 Alarm 4 8 Alarm 7 9 Alarm Relay NO 10 Data 1 11 Alarm 2 12 Alarm 5 13 Alarm 8 14 Alarm Relay NO 15 Data 2 NO Normally Open Screen 15 Front Panel and Back Panel ...

Page 16: ...LTC 5104 LTC 5108 Series Instruction Manual Illustrations EN 16 Bosch Security Systems 7 April 2004 Screen 17 Typical Installation Using LTC 5108 Series Switcher DVR or VCR ...

Page 17: ...LTC 5104 LTC 5108 Series Instruction Manual Font Tables EN 17 Bosch Security Systems 7 April 2004 7 FONT TABLES ...

Page 18: ...LTC 5104 LTC 5108 Series Instruction Manual EN 18 Bosch Security Systems 7 April 2004 ...

Page 19: ...LTC 5104 LTC 5108 Series Instruction Manual EN 19 Bosch Security Systems 7 April 2004 ...

Page 20: ... Systems Inc 850 Greenfield Road Lancaster PA 17601 USA Tel 800 326 3270 Fax 1 717 735 6560 www boschsecuritysystems com Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Tele 31 40 27 80000 Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Republic of Singapore Tel 65 6 319 3486 ...

Reviews: