LTC 5104, LTC 5108 Series
|
Instruction Manual
|
Installation
4.11 Alarm Capture
This menu item appears only if the
Auto Alarm
reset
mode is selected (see SCREEN 5). When the
Alarm
Capture
is ON, alarm call ups are held for at least the
length of their
Alarm Capture Time
. After its
Alarm
Capture Time
has expired, the alarm call up remains as
long as its contact closure exists. When the
Alarm
Capture
is OFF, alarm call ups are held only as long as
its contact closure is detected. The default is ON.
Screen 5
4.12 Alarm Capture Time
This menu item appears only when the
Alarm Capture
is ON (see SCREEN 6). The
Capture Time
specifies the
minimum length of time that the alarm call up will be
held, once its contact closure is detected. During
multiple alarms, the
Capture Time
expires only while
the alarm is being displayed. Use
SKIP/clr
to
decrease time and
ALARM
to increase time. Alarm
capture time can be set from 1 second to 63 seconds.
The default time is 14 seconds.
Screen 6
4.13 Alarm Dwell Time
The
Alarm Dwell Time
determines how long each alarm
call up is displayed during sequencing of multiple
alarms (see SCREEN 7). Use
SKIP/clr
to decrease
time and
ALARM
to increase time.
Alarm Dwell Time
can be set from 1 second to 64 seconds. The default
time is two seconds.
Screen 7
4.14 Alarm Contact Closures
This screen enables the user to set alarm contact
closures as NORMALLY OPEN or NORMALLY
CLOSED. Press
SKIP/clr
to choose between the two
options. The default is NORMALLY OPEN (see
SCREEN 8).
Screen 8