Installation
en
17
4.
Screw in the filler strip fully.
5.
Push in the fastening bolt and turn it 90°.
Note:
The fastening pieces on the left and right of
the appliance must be able to move.
Final fitting stage
1.
Slide the appliance up into place.
¨
2.
Lock the fastening bolts on the left and right.
©
3.
Fit the protective caps on the left and right.
ª
4.
Establish the electrical connection.
Note:
The extractor hood's housing can be concealed
within the upper cabinet. In doing so, you must observe
the following:
■
The intermediate floor must not be placed on the
extractor hood's housing.
■
The front panel must not be secured to the housing.
■
Access must be available in order to change the
filter and for the after-sales service.
Appliance width 90 cm:
You must also screw the appliance to the wall-hanging
cupboards either side of it.
Changing the filter pull-out's limit stop
On some versions of the appliance, the limit stop for the
filter pull-out can be changed. Spacers are included
with these appliances in order to position the
appliance's handle strip flush with the fitted unit.
1.
Pull the filter pull-out towards you.
2.
Shorten the spacer to the required dimension and
insert it into the slot specified.
[
%
$
&
Summary of Contents for LI67SA560B