Decommissioning | KTS 515 | 19
en
1 689 989 232
2019-01-04
|
Robert Bosch GmbH
6. Decommissioning
6.1
Temporary shutdown
In the event of lengthy periods of non-use:
6.2
Change of location
¶
If the KTS 515 is passed on, all the documentation
included in the scope of delivery must be handed over
together with the unit.
¶
The KTS 515 is only ever to be transported in the
original or equivalent packaging.
¶
Unplug the electrical connection.
¶
Heed the notes on initial commissioning.
¶
Disconnect the KTS 515 from the mains.
6.3
Disposal and scrapping
1.
Disconnect the KTS 515 from the mains and detach
the power cord.
2.
Dismantle the KTS 515 and sort out and dispose
of the different materials in accordance with the
applicable regulations.
6.4
Disposal
KTS 515 satisfies the criteria of the
European Directive WEEE 2012/19/EU.
Old electrical and electronic devices,
includingcables and accessories or batteries
must be
disposed of separate to household
waste.
¶
Please use the return and collection
systems in place for disposal in your area.
¶
Damage to the environment and hazards to
personal health are prevented by properly
disposing of KTS 515.
7. Technical data
7.1
General data
Property
Value/Range
Operating voltage
7 VDC — 30 VDC
Power consumption through vehicle
battery or power supply
approx. 6 Watt
Dimensions (L x W x H)
170 x 120 x 40 mm
Weight (without connecting cables)
325 g
Degree of protection
IP 20
Operating temperature
5 °C – 40 °C
41 °F – 104 °F
Storage Temperature
-25 °C – 60 °C
-13 °F – 140 °F
Relative operating humidity
<90 % non-
condensing
7.2
Interface protocols
In accordance with ISO 15031 the following interfaces
and the corresponding protocols are supported for
control unit diagnosis:
R
ISO/DIS 15765-4 (CAN) - baud rates: 250 kbit/s and
500 kbit/s)
R
ISO 9141-2 Fast
R
ISO/DIS 14230-4 (keyword protocol 2000) 5 baud
R
ISO/DIS 14230-4 (keyword protocol 2000) Fast
R
ISO/DIS 11519-4 (SAE J1850) PWM
R
ISO/DIS 11519-4 (SAE J1850) VPW
and
R
ISO 27145 (WWH-OBD)
R
SAE J1939
7.3
Power pack
Property
Value/Range
Input voltage
100 VAC— 240 VAC
Input frequency
47 Hz — 63 Hz
Output voltage
15 V
Output current
1,66 A
Operating temperature
0 °C — 40 °C
7.4
Bluetooth Class 1
Wireless connection
KTS 515 to PC/Laptop
Minimum range
Workshop environment in the open
space
30 meters
If the vehicle door or window is open
and the engine is still running in the
vehicle interior
10 meters
7.5
RED (Radio Equipment Directive)
Wireless link
Frequency band
Maximum radiated
transmitter power
output
Bluetooth
2,4 GHz
19,9 dBm