![Bosch KTS 350 Original Instructions Manual Download Page 27](http://html.mh-extra.com/html/bosch/kts-350/kts-350_original-instructions-manual_50710027.webp)
1 689 989 293
2020-08-24
|
Robert Bosch GmbH
Technical Data | KTS 350 (KTS 3a Series) | 27 |
9.5
Interface protocols
The following interfaces and their associated protocols
are supported for control unit diagnosis in compliance
with ISO 15031:
R
ISO 15031, ISO 22900
R
SAE J2534-1 and -2 (PassThru)
R
ISO 13400 (Diagnostic over IP)
R
ISO 9141-2 (communication lines K and L)
R
SAE J1850VPW and SAE J1850PWM
(communication lines BUS+ and BUS-)
R
CAN ISO 11898 ISO 15765-4 (OBD)
(communication lines CAN-H and CAN-L)
R
CAN Single Wire, CAN Low Speed and additional
vehicle-specific special protocols
i
KTS 350 (KTS 3a Series) may be used for Euro
5-compatible vehicles with the PassThru Standard.
9.6
Power supply unit
Property
Value / range
Input voltage (AC)
100 – 240 VAC
Frequency
50 / 60 Hz
Input current
1.6 A
Output voltage (DC)
12 V
Max. output current
5.0 A
en
Summary of Contents for KTS 350
Page 2: ......