Photobeam 5000
Wiring | en
13
Wiring
Refer to Terminal strip below for transmitter/receiver terminal locations. Use duct
pipes for outdoor wiring. Do not use aerial wiring.
!
Caution!
Complete all electrical connections and inspect them prior to applying power.
Notice!
Tamper and EDC terminals should be connected to a 24-hour supervisory loop
Notice!
Power is to be provided by a UL Listed burglar alarm power supply or burglar alarm control
panel. In case of power failure, the power supply or control unit shall have a minimum of 4
hours of standby power.
Notice!
All wiring is to be in accordance with the National Electric Code, ANSI/NFPA 70.
Notice!
This system should be tested at least once a week to ensure proper function.
Terminal strip overview
1
2
3
4
3
5
6
4
Figure 4.1: Terminal strip component overview
Callout
﹘
Description
Callout
﹘
Description
1
ー
Receiver
4
ー
Tamper
2
ー
Transmitter
5
ー
Alarm output
3
ー
Power (non-polarized)
6
ー
EDC output
Bosch Security Systems, Inc.
Installation and Operation Guide
2016.02 | 03 | F.01U.303.478