background image

 

 

__________________________________________________________________________________________________________________ 

Edition: October 2013 Document N°: F.01U.136.807 V2 

 

Page 10 of 10 

 
 

FCC Statement for Class B digital device 

 

Note

This equipment has been tested and found to comply with the limits for a Class B digital de-
vice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in accordance 
with the instructions, may cause harmful interference to radio communications. However, 
there is no guarantee that interference will not occur in a particular installation. If this equip-
ment does cause harmful interference to radio or television reception, which can be deter-
mined by turning the equipment off and on, the user is encouraged to try to correct the inter-
ference by one or more of the following measures: 
• 

Reorient or relocate the receiving antenna. 

• 

Increase the separation between the equipment and receiver. 

• 

Connect the equipment into an outlet on a circuit different from that to which the re-

ceiver is connected. 
• 

Consult the dealer or an experienced radio/TV technician for help. 

Summary of Contents for IS76

Page 1: ...____________________________________________________________________________________________________ Edition October 2013 Document N F 01U 136 807 V2 Page 1 of 10 IS76 Beacon with Ferrite Antenna Installation Manual ...

Page 2: ... GmbH Haus ServiceRuf Robert Bosch Ring 5 D 85630 Grasbrunn Germany Phone 49 0 89 6290 0 Fax 49 0 89 6290 1020 E mail de securitysystems bosch com www bosch sicherheitsprodukte de Bosch Security Systems Ltd Broadwater Park North Orbital Road Denham UB9 5HN United Kingdom Phone 44 0 1895 834 466 Fax 44 0 1895 878 089 E mail uk securitysystems bosch com www boschsecurity co uk Bosch Security Systems...

Page 3: ...0 Content Locator Function 4 IS76 Beacon with Ferrite Antenna 4 IS76 Ferrite Antenna 4 IS76 Ferrite Beacon Controller 5 System Supervision 5 Features of the IS76 Beacon System 5 IS76 Ferrite Antenna 6 IS76 Beacon Controller 6 Connection Compartment 7 Enable Locator Function in NurseCall System 7 Configuration and Wiring 8 Ferrite Beacon Antenna 9 Ferrite Beacon Controller 9 ...

Page 4: ...the actual position is indicated additionally on the NurseCall units This information can be made visible by pressing the yellow button on the NurseCall Main or Relay Unit Locator information block 255 positions POS 000 254 can be differentiated When passing beacon modules with position numbers 231 254 the transmitters S37L and S35L can send a call for help auto matically without manual activation...

Page 5: ...ounted indoors in a well ventilated cool place Connection compartment Supervision Signal lamp LED Figure 1 System Supervision The operation of the IS76 Beacon system is supervised An eventual operation failure broken wire or overload is indicated by the front panel LED and by the opening of a normally closed relay contact that is accessible from the terminal block The supervision output may be con...

Page 6: ... avoid overheating of the IS76 Beacon Controller install the antenna at least 1 5 cm away from metallic frames or surfaces IS76 Beacon Controller The IS76 Beacon Controller can be fixed with two to five screws on the wall Two holes at 60 mm interval are provided for direct mounting on connection boxes The three upper holes are used for positioning the device and cannot be reached from the Connecti...

Page 7: ...enna s Connection of the wired supervision output Setting of the Location identification code Can be carried out in the connection compartment It is reached by taking off the lower part of the housing see This can be done even if the device is fixed on the wall The connection cables can be channelled towards the outside through the hole next to the terminal blocks or downwards by breaking off part...

Page 8: ...Signal Lamp Green ok Red operation failure Ferrite Beacon Antenna A Ferrite Beacon Antenna B Supervision O utput Power Supply 24 VDC Supervision of Beacon A Supervision of Beacon B Enabled Disabled Antenna B is optional It is used to extend the capture range on large double doors RAC optional Blue Blue White White Polarity of the antenna and the wiring has to be respected when two antennas are use...

Page 9: ...extended up to 10 m Operation Range1 typ 2 6 m typ 3 6 m Antenna 1 When used in conjunction with S37L Wristband Transmitters of REV B and higher Ferrite Beacon Controller Housing Plastic case ASA For wall mounting L x H x P 133 x 82 x 26 mm Weight about 200 g AC Power supply included 100 240 VAC DC Power supply 22 24 VDC max 400 mA 1 antenna Max 800 mA 2 antennas Frequency 68 kHz Supervision Outpu...

Page 10: ... energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equip ment does cause harmful interference to radio or television reception which can be deter mined by turning the equipment off and on the user is encouraged to try to c...

Reviews: