ICP-CC404
|
Installation Guide | 14.0 Zone Information
Bosch Security Systems, Inc. | 12/08 | F01U089401-02
55
The Zone Report Code determines whether the
control panel sends Alarm Reports for the zone.
Refer to Section
14.3.7 Zone Report Code
on page 59
for more information.
The Zone Dialer Options location enables you to
specify how a zone sends a report to a base station
receiver. Refer to
Section 14.3.8 Zone Dialer Options
on
page 59 for more information.
Zone Defaults
The default zone parameters for the ICP-CC404
Control Panel are listed in
Table 43
. You can program
Zones 1 to 4 as any Zone Type, but you can only
program Zones 5 to 8 as a 24-Hour Zone Type.
Table 43:
Zone Programming Defaults
Zone
Number
Default
Type
Locations
Zone
Type
Pulse
Count
Pulse
Time
Zone
Options 1
Zone
Options 2
Report
Code
Dialer
Options
Zone 1
Delay 1
267 to 273
2
0
0
1
14
1
1
Zone 2
Handover
274 to 280
1
0
0
1
14
1
1
Zone 3
Handover
281 to 287
1
0
0
1
14
1
1
Zone 4
Instant
288 to 294
0
0
0
1
14
1
1
Zone 5
Fixed 24-hr burglary
295 to 301
12
0
0
1
12
1
1
Zone 6
Fixed 24-hr burglary
302 to 308
12
0
0
1
12
1
1
Zone 7
Fixed 24-hr fire
309 to 315
13
0
0
1
12
1
1
Zone 8
Fixed 24-hr tamper
316 to 322
9
0
0
1
12
1
1
14.3.1 Zone
Types
0 – Instant Zone
An Instant Zone (Contact ID Event Code 130)
immediately sounds the sirens and operates the dialer
when it is unsealed after the Exit Timer expires.
If an Instant Zone is not restored when the system is
disarmed, a Zone Restore Report is automatically sent
to the receiving party.
1 – Handover Zone
A Handover Zone (Contact ID Event Code 130) acts
as an Instant Zone if it is activated by itself. If a
Handover Zone is activated after a Delay Zone, the
remaining Delay Time is handed over from the Delay
Zone to the Handover Zone.
Handover can be sequential or non-sequential. The
default settings is sequential handover. You can
disable sequential handover by disabling Option 8 in
Location 426 (refer to
Section 18.3 System Options 3
on
page 74).
If a Handover Zone is not restored when the system
is disarmed, a Zone Restore Report is automatically
sent to the receiving party.
2 – Delay-1 Zone
A Delay-1 Zone (Contact ID Event Code 130) has a
delay time determined by the value in Locations 398
and 399 (refer to
Section 17.2 Entry Timer 1
on
page 70). After Entry Time expires, the system
activates an alarm.
If a Delay-1 Zone is not restored when the system is
disarmed, a Zone Restore Report is sent to the
receiving party.
3 – Delay-2 Zone
A Delay-2 Zone (Contact ID Event Code 130) has a
delay time determined by the value in Locations 400
and 401 (refer to
Section 17.3 Entry Timer 2
on
page 71). After Entry Time expires, the system
activates an alarm.
If a Delay-2 Zone is not restored when the system is
disarmed, a Zone Restore Report is sent to the
receiving party.
4 – Reserved
5 – Reserved
6 – 24-Hour Medical Zone
A
24-
Hour Medical Zone (Contact ID Event Code
100) is always ready to activate the dialer, horn
speaker, bell, and strobe, regardless of whether the
system is armed or disarmed. A Medical Report is
sent to the base station receiver. A 24-Hour Medical
Zone does not send a Restore Report until the zone is
restored.
7 – 24-Hour Panic Zone
A 24-Hour Panic Zone (Contact ID Event Code 120)
is always ready to activate the dialer, horn speaker,
bell, and strobe, regardless of whether the system is
armed or disarmed. A Panic Report is sent to the base
station receiver. A 24-Hour Panic Zone does not send
a Restore Report until the zone is restored.