Table 6:
Command 965 Defaults
Location
Description
Default Value
Setting
032
Handshake Tone for Receiver 1
1
(Handshake Tone)
033 Transmission
Format
4
(Domestic)
034 to 039
Subscriber ID Number
0, 0, 0, 0, 0,
1
(1
Beep)
332
Zone Status Reporting Options
2
(Receiver
2
only)
333 and 334
Open/Close Reports
11, 12
(Open/Close
Reports)
335
Open/Close Reporting Options
2
(Receiver
2
only)
356 to 358
System Status – Access Denied
6, 7, 12
(Access
Denied)
359
System Status Reporting Options
2
(Receiver
2
only)
360 to 366
Test Report Time
0, 0, 0, 0,
7, 1, 0
(Test
Reports)
367
Test Reporting Dialer Options
1
(Receiver
1
only)
Example (Auto Step Mode Enabled)
To enter the Primary Telephone Number 02 (pause)
9672 1055 when Auto Step Mode is enabled:
1.
Press [0 #].
You are positioned at Location 000 (the Primary
Telephone Number for Receiver 1).
2.
To program the number, press:
[10 * 2 * 13 * 9 * 6 * 7 * 2 * 1 * 10 * 5 * 5 * 0*]
Example (Auto Step Mode Disabled)
To enter the Primary Telephone Number 02 (pause)
9672 1055 when Auto Step Mode is disabled:
1.
Press [0 #].
You are positioned at Location 000 (the Primary
Telephone Number for Receiver 1).
2.
To program the number, press:
[10 * # 2 * # 13 * # 9 * # 6 * # 7 * # 2 * # 1 * #
10 * # 5 * # 5 * # 0 *]
2.4.10 Command 999 – Display the Panel Type or
Software Version Number
When using the remote codepad, this command
shows the version of the control panel. Because
different control panels use the same printed circuit
board (PCB), it is difficult to determine the control
panel the PCB is set to.
To show the control panel type or software
version number:
1.
Enter the Installer Code (the default is 1234) and
press [#] to enter Installer’s Programming Mode.
Two beeps sound and the remote codepad shows
the data programmed in Location 000.
If you are using the remote codepad, the STAY
and AWAY indicators flash to indicate you
entered Installer’s Programming Mode.
2.
Enter [9 9 9 #].
Two beeps sound.
If you are using the remote codepad, the codepad
displays a zone indicator corresponding to the
control panel type. Refer to
Table 7
for more
information.
Table 7:
Control Panel Type
Indicator Control
Panel
Type
4
ICP-CC404
8 ICP-CC408
ICP-CC488
3.
Press [#] to exit from this command and return to
the Installer’s Programming Mode.
4.
Enter [9 6 0 #] to exit from the Installer's
Programming Mode.
Two sound and the system returns to the