en
Installation instructions
50
5. Note:
To ensure that no scratches are formed on
the matte glass plate, do not allow the underside of
the hob to come into contact with objects.
Hold the front section of the hob and tilt it upwards
at a maximum angle of 30°. Secure the hob with
the profile bar by placing it vertically on the front
burner mount.
6.
Remove the plastic covers from the front profiles on
the right and left. Ensure that the covers are not
damaged or scratched. Unscrew the screws (T20)
below these.
7. Note:
Remove the screws that are mentioned below
so that the switch and the electronic parts are not
damaged.
Remove the four screws (M4) that are uncovered
when you remove the control knobs (T15) from the
control panel.
8. Note:
In order to access the bypass nozzles on the
right-hand side, turn the control panel clockwise
slightly. In order to access the bypass nozzles on
the left side, turn the control panel anti-clockwise
slightly. Ensure that the cables are not damaged
and the connections do not come loose.
Grip the panel with both hands and slowly pull it up-
wards. Remove the panel from the fastening lugs.
Then carefully pull the panel forwards to remove it.
Ensure that the cables are not damaged and that
the connections do not come loose.
Replacing bypass nozzles
1.
Use a flat-head screwdriver (no. 2) to unscrew the
bypass nozzles. Remove the bypass nozzles.
2.
Select the appropriate replacement bypass nozzles
from the table. You can find additional information
about this in the section entitled "Technical data –
Gas" →
.
3.
Check that the seals on the bypass nozzles are
seated correctly and work properly. Only use by-
pass nozzles with absolutely faultless seals.
4.
Insert the new bypass nozzles and tighten them se-
curely. Ensure that all bypass nozzles have been
fastened to the correct taps.