23
4.
Replace the gas label with the new label that was supplied
with the nozzle set.
5.
To reassemble the oven burner and the floor plate, follow the
instructions in reverse order.
Setting the minimum gas flow
1.
Open the appliance door.
2.
Press the control knob for the oven and turn it anti-clockwise
to the maximum position of 275. The gas burner ignites. Hold
the control knob depressed for around 15 seconds and then
release it.
3.
Close the appliance door.
4.
Pull out the control knob.
5.
Through the gas tap opening in the control panel, loosen the
internal setting screw.
6.
Replace the control knob and heat the oven for 15 minutes.
7.
Then turn the control knob to the minimum position "Min"
140.
8.
Pull out the control knob again.
9.
Now, through the gas tap opening in the control panel, adjust
the internal setting screw until a stable flame is burning
correctly.
Loosen the adjuster screw to increase the gas flow or tighten
it to decrease the gas flow. The setting is correct when the
height of the small flame is approx. 3 to 4 mm.
In the case of a liquefied gas connection, tighten the setting
screw.
10.
Refit the control knob.
11.
Make sure that the flame does not go out when the gas flow
is changed quickly from maximum to minimum and vice
versa, and when the appliance door is opened and closed.
Grill burner
Replacing the nozzles
1.
Unscrew the screw on the right on the grill burner and pull
the burner to the right out of the gas connection.
The burner is still connected on the left side to a cable for the
electric ignition.
2.
Place the burner carefully down with the right side on the
cooking compartment floor.
3.
Unscrew the nozzle and replace it with a nozzle which is
suitable for the new type of gas (see "General nozzle table"
section).
4.
Replace the gas label with the new label that was supplied
with the nozzle set.
5.
To reassemble, follow the instructions in reverse order.
Setting the minimum gas flow
1.
Open the appliance door.
2.
Press the control knob for the oven and turn it anti-clockwise
to maximum position "Max". The gas burner ignites. Hold the
control knob depressed for around 15 seconds and then
release it.
3.
Close the appliance door.
4.
Remove the control knob.
5.
Through the gas tap opening in the control panel, loosen the
internal setting screw.
6.
Replace the control knob and heat the oven for 15 minutes.
7.
Then turn the control knob to the minimum position "Min".
8.
Pull out the control knob again.
9.
Now, through the gas tap opening in the control panel, adjust
the internal setting screw until a stable flame is burning
correctly.
Loosen the adjuster screw to increase the gas flow or tighten
it to decrease the gas flow. The setting is correct when the
height of the small flame is approx. 3 to 4 mm.
In the case of a liquefied gas connection, tighten the setting
screw.
10.
Refit the control knob.
11.
Make sure that the flame does not go out when the gas flow
is changed quickly from maximum to minimum and vice
versa, and when the appliance door is opened and closed.