2.2 High-voltage
capacitor
The high-voltage capacitor can be tested by ‘ohmic’ measurement’
(resistance measurement range 20
ΜΩ
).
A correctly functioning capacitor indicates transient continuity.
The resistance then increases proportionally with the load.
A defective capacitor (e.g. short-circuit) indicates permanent
continuity.
The measuring instrument must indicate infinitely between the
connection and housing.