1.3 Leak test (leak detection measurement)
1.3 Leak test (leak detection measurement)
The leak rate is the microwave energy which escapes despite the
intact sealing systems.
The leak rate is the microwave energy which escapes despite the
intact sealing systems.
The leak rate is measured as an energy density with suitable
measuring instruments at a distance of 5 cm. The unit of
measurement is mW/cm
2.
The leak rate is measured as an energy density with suitable
measuring instruments at a distance of 5 cm. The unit of
measurement is mW/cm
The limiting values for the permitted measured values, as well as
the measurement conditions, have been specified in the VDE
regulation 0700/Part 25 and are as follows:
The limiting values for the permitted measured values, as well as
the measurement conditions, have been specified in the VDE
regulation 0700/Part 25 and are as follows:
1.3.1 Normal operation with load
1.3.1 Normal operation with load
Setting:
maximum power setting of the appliance
Setting:
maximum power setting of the appliance
Load:
275
cm
3
water
Load:
275
cm
Permitted limiting value: 5 mW/cm
2
Permitted limiting value: 5 mW/cm
Measurement distance: 5 cm
Measurement distance: 5 cm
2.
3
water
2
1.3.2 Abnormal operation (no-load operation)
Setting:
maximum power setting of the appliance
Load:
none (no-load operation)
Permitted limiting value: 10 mW/cm
2
Measurement distance: 5 cm
Page 3 of 23 pages
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
______________________________________________________________________________________________________________________________________________________________________________
Copyright by BSH Home Appliances Corporation 1901 Main Street, Suite 600, Irvine CA 92614 700_ 58300000192890_ARA_EN_A 800 444-9091