background image

Page 1 of 1

Service Bulletin

b

1st Edition/Revision 1

July, 2003

Technical Support

1-888-522-6724

The conversion of 400/500/600 series wall ovens from 240V to 208V is achieved by 
removing the “U” shaped connector pin from the single terminal position #1 and 
inserting it across terminal positions 1 and 2 as explained below.

PROCEDURE:

ˆ

 Using a Phillips head 

screwdriver, remove the back 
access panel.

(NOTE: Do NOT remove the 

entire back panel.)

ˆ

 Locate the main terminal 

block and verify that the pin 
is in the 240V position (

A

).

ˆ

 Unscrew the first screw (in 

position #1) on the main 
terminal block and remove 
the pin (

B

).

(NOTE: Take care not to drop 

the pin down into the back 
panel.)

ˆ

 Loosen the second screw (in 

position #2) on the main 
terminal block and insert the 
pin into the 208V position 
(between the first and 
second screws) (

C

).

ˆ

 Tighten the screws and 

reattach the back access 
panel.

C

Pin in 208V

position

#2 screw

B

#1 screw

Main terminal block

Pin in 240V

position

A

Conversion of 400/500/600 Series Wall Ovens from 240V to 208V Operation