en
Installation instructions
32
24.4 Installation underneath a hob
If the appliance is installed under a hob, the following
minimum dimensions must be adhered to (including
substructure, if applicable).
The minimum worktop thickness a is based on the
required minimum clearance .
Hob type
a raised in mm
a flush in mm
b in mm
Induction hob
37
38
5
Full-surface induction hob
47
48
5
Gas hob
27
38
5
Electric hob
27
30
2
24.5 Installation in a tall unit
Observe the installation dimensions and the installation
instructions when installing in a tall unit.
¡
To ventilate the appliance, the intermediate floors
must have a ventilation cut-out.
¡
If the tall unit has another back panel in addition to
the element back panels, this must be removed.
¡
Only fit the appliance up to a height which allows
accessories to be easily removed.
24.6 Corner installation
Observe the installation dimensions and the installation
instructions when installing in a corner.
¡
To ensure that the appliance door can be opened,
you must take the minimum dimensions into consid-
eration when installing in a corner. The dimension
is dependent on the thickness of the unit front and
the handle.
24.7 Electrical connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
¡
The appliance corresponds to protection class I and
must only be operated with a protective earth con-
nection.
¡
The fuse protection must correspond to the power
rating specified on the appliance's rating plate and
to local regulations.
¡
The appliance must be disconnected from the
power supply whenever installation work is being
carried out.