24
| English
ive tool does not brush against the protective guard or
other parts.
A plastic part (O-ring) is fitted around the cent-
ring collar in the mounting flange
(12)
.
If the
O-ring is missing or damaged,
the mounting
flange
(12)
must be replaced before operation
can resume.
Quick-clamping nut
To change the abrasive tool easily without having to use any
additional tools, you can use the quick-clamping nut
(20)
in-
stead of the clamping nut
(19)
.
u
The quick-clamping nut
(20)
may be used only for
grinding or cutting discs.
Only use quick-clamping nuts (20)
that are in good work-
ing order and not damaged.
When screwing on, make sure that the printed side of the
quick-clamping nut
(20)
is not facing the grinding disc;
the arrow must be pointing towards the index mark (30).
(30)
Press the spindle lock button
(1)
to
lock the grinding spindle. To tighten
the quick-clamping nut, turn the grind-
ing disc firmly clockwise.
If the quick-clamping nut has been at-
tached correctly and is not damaged,
you can loosen it by hand by turning
the knurled ring anticlockwise.
Never
loosen a tight quick-clamping nut
with pliers. Always use the combin-
ation wrench.
Insert the combination
wrench as shown in the figure.
Approved abrasive tools
You can use all the abrasive tools mentioned in these operat-
ing instructions.
The permissible speed [min
-1
] or the circumferential speed
[m/s] of the abrasive tools used must at least match the val-
ues given in the table.
It is therefore important to observe the permissible
rota-
tional/circumferential speed
on the label of the abrasive
tool.
max. [mm]
[mm]
[°]
D
b
s
d
α
[min
-1
] [m/s]
115
125
7
7
–
–
22.2
22.2
–
–
11,000
11,000
80
80
115
3
–
22.2
–
11,000
80
max. [mm]
[mm]
[°]
D
b
s
d
α
[min
-1
] [m/s]
125
3
–
22.2
–
11,000
80
115
125
–
–
–
–
–
–
–
–
11,000
11,000
80
80
75
30
–
M 14
–
11,000
80
115
115
125
125
24
19
24
19
–
–
–
–
M 14
22.2
M 14
22.2
–
–
–
–
11,000
11,000
11,000
11,000
80
80
80
80
125
–
–
M 14
–
11,000
80
83
–
–
M 14
–
11,000
80
α
s
115
125
2.4
2.4
10
10
22.2
22.2
> 0
> 0
11,000
11,000
80
80
Rotating the Machine Head
u
Pull the plug out of the socket before carrying out any
work on the power tool.
The machine head can be rotated in
90° increments. In this way, the on/off
switch can be brought into a more fa-
vourable handling position for particu-
lar applications, e.g. for left-handed
tool users.
Completely unscrew the four screws. Rotate the machine
head carefully,
without removing it from the housing
, into
the new position. Screw in and retighten the four screws.
Dust/Chip Extraction
The dust from materials such as lead paint, some types of
wood, minerals and metal can be harmful to human health.
Touching or breathing in this dust can trigger allergic reac-
tions and/or cause respiratory illnesses in the user or in
people in the near vicinity.
Certain dusts, such as oak or beech dust, are classified as
carcinogenic, especially in conjunction with wood treatment
additives (chromate, wood preservative). Materials contain-
ing asbestos may only be machined by specialists.
– Use a dust extraction system that is suitable for the ma-
terial wherever possible.
– Provide good ventilation at the workplace.
– It is advisable to wear a P2 filter class breathing mask.
1 609 92A 7C4 | (24.11.2022)
Bosch Power Tools
Summary of Contents for GWS 700
Page 3: ... 3 A B C D 11 8 11 8 11 8 8 11 Bosch Power Tools 1 609 92A 7C4 24 11 2022 ...
Page 5: ... 5 26 22 28 24 25 23 27 21 5 6 29 Bosch Power Tools 1 609 92A 7C4 24 11 2022 ...
Page 329: ...한국어 329 전동공구를 가정용 쓰레기로 처리하지 마십시오 Bosch Power Tools 1 609 92A 7C4 24 11 2022 ...
Page 352: ...352 standard Inox standard Metal 1 609 92A 7C4 24 11 2022 Bosch Power Tools ...
Page 354: ...354 1 609 92A 7C4 24 11 2022 Bosch Power Tools ...
Page 358: ...IV 1 609 92A 7C4 24 11 2022 Bosch Power Tools ...