English |
25
Bosch Power Tools
2 609 141 026 | (1.7.13)
With exception of the “Permanent laser beam” setting, all ba-
sic settings are retained when switching off.
Continuous Laser Beam
Do not point the laser beam at persons or animals and
do not look into the laser beam yourself, not even from
a large distance.
In this setting, the laser beam also remains switched on be-
tween measurements; for measuring, it is only required to
press the measuring button
2
once.
Measuring Functions
Simple Length Measurement
For length measurements, press button
12
until the “length
measurement” indication appears on the display.
To switch the laser on and for measuring,
briefly press the measuring button
2
once
each time.
The measured value is displayed in the re-
sult line
c
.
For several subsequent length measurements, the last meas-
ured results are displayed in the measured-value lines
a
.
Area Measurement
For area/surface measurements, press button
12
until the in-
dicator for area measurement
appears on the display.
Afterwards, measure the length and the width, one after an-
other, in the same manner as a length measurement. The laser
beam remains switched on between both measurements.
Upon completion of the second measure-
ment, the surface is automatically calcu-
lated and displayed in the result line
c
.
The individual measured values are dis-
played in the measured-value lines
a
.
Volume Measurement
For volume measurements, press button
12
until the indica-
tor for volume measurement
appears on the display.
Afterwards, measure the length, width and the height, one af-
ter another, in the same manner as for a length measurement.
The laser beam remains switched on between all three meas-
urements.
Upon completion of the third measure-
ment, the volume is automatically calcu-
lated and displayed in the result line
c
.
The individual measured values are dis-
played in the measured-value lines
a
.
Values above 1000000 m
3
cannot be indicated;
“ERROR”
appears on the display. Divide the volume to be measured in-
to individual measurements; their values can then be calculat-
ed separately and then summarized.
Continuous Measurement (Tracking) / Minimum/Maxi-
mum Measurement (see figure B)
For continuous measurements, the measuring tool can be
moved relative to the target, whereby the measuring value is
updated approx. every 0.5 seconds. In this manner, as an ex-
ample, you can move a certain distance away from a wall,
while the actual distance can always be read.
For continuous measurements, press function mode button
8
until the indicator for continuous measurement appears on
the display. To start the continuous measurement, press the
measuring button
2
.
The minimum measurement is used to determine the shortest
distance from a fixed reference point. It is used, as an exam-
ple, for determining plumb lines or horizontal partitions.
The maximum measurement is used to determine the greatest
distance from a fixed reference point. It is used, as an exam-
ple, for determining diagonals.
The current measuring value is displayed
in the result line
c
. The maximal (
“max”
)
and the minimal (
“min”
) measuring value
are displayed in the measured-value lines
a
. It is always overwritten, when the cur-
rent length measurement value is less
than the present minimal or larger than
the present maximal value.
The previous minimal and maximal values are deleted by
pressing the button for clearing the internal memory
4
.
Pressing the measuring button
2
ends the continuous meas-
urement. The last measured value is displayed in the result
line
c
. Pressing the measuring button
2
again restarts a con-
tinuous measuring run.
Display Illumination
On
Off
Auto on/off
Digital vial
On
Off
Display rotation
On
Off
Permanent laser beam
On
Off
Unit of measure, distance
(depending on country ver-
sion)
m, ft, inch, ...
Unit of measure, angle
°, %, mm/m
Basic Settings