Technical data | FSA 720 | 25
en
8. Technical data
8.1
Measuring functions
8.1.1
Engine test
Measuring functions
Measurement range
Resolution Sensors
Speed
450 rpm – 6000 rpm
100 rpm – 12000 rpm
250 rpm – 7200 rpm
100 rpm – 500 rpm
10 rpm
10 rpm
10 rpm
10 rpm
Connecting cable B+/B–
Trigger clamp, Secondary sensor,
Primary connecting cable (UNI 4)
Current clamp 30A, Diesel clip-on sensor,
Current clamp 1000 A (starter current)
Oil temperature
-20 °C – 150 °C
0,1 °C
Oil temperature sensor
U battery
0 – 60 V
0,1 V
Connecting cable B+/B–
U term. 15
0 – 60 V
0,1 V
Primary connecting cable (UNI 4)
U term. 1
0 – 20 V
50 mV
Primary connecting cable (UNI 4)
Ignition voltage,
Spark voltage
±500 V
±50 kV
1 V
100 V
Primary connecting cable (UNI 4),
Secondary sensor
Spark duration
0 – 6 ms
0,01 ms
Primary connecting cable (UNI 4),
Secondary sensor
Relative compression via starter current
0 – 200 Ass
0,1 A
Primary connecting cable (UNI 4),
Secondary sensor
U generator ripple
0 – 200 %
0,1 %
Multi measuring cable CH1
I starter
I generator
I spark plugs
0 – 1000 A
0,1 A
Current clamp 1000 A
I primary
0 – 30 A
0,1 A
Current clamp 30 A
Closing angle
0 – 100 %
0 – 360 °
0,1 %
0.1 °
Primary connecting cable (UNI 4)
Closing time
0 – 50 ms
0,01 ms
0,1 ms
Secondary sensor
Current clamp 30 A
Ignition point,
Ignition advance with Stroboscope
0 – 60 °KW
0,1 °KW
Trigger clamp
Start-of-delivery, start of injection,
Timing:
With Stroboscope
0 – 60 °KW
0,1 °KW
Clip-on sensor
Pressure (Air)
-800 hPa – 1500 hPa
1 mbar
Air pressure sensor
Pulse duty factor t-/T
0 – 100 %
0,1 %
Multi measuring cable CH1 / CH2
Injection time
0 – 25 ms
0,01 ms
Multi measuring cable CH1 / CH2
Glow time
0 – 20 ms
0,01 ms
Multi measuring cable CH1 / CH2
8.1.2
Multimeter
Measuring functions
Measurement range
Resolution
Sensors
Speed
as for engine test
U battery
0 - 60 V
0,01 V
Connecting cable B+/B–
U term. 15
0 - 60 V
1)
0,1 V
Primary connecting cable (UNI 4)
U-DC
min./max.
±200 mV – ±20 V
±20 V – ±200 V
1)
0,001 V
0,01 V
Multi measuring cable CH1 / CH2
I-1000 A
±1000 A
0,1 A
Current clamp 1000 A
I-30 A
±30 A
0,01 A
Current clamp 30 A
Resistance
(R-Multi 1)
0 – 1000 Ω
1 kΩ – 10 kΩ
10 kΩ – 999 kΩ
0,001 Ω
0,1 Ω
100 Ω
Multi measuring cable CH1
Pressure P-air
0,2 hPa – 2500 hPa
0,1 hPa
Air pressure sensor
Oil temperature
-20 °C – 150 °C
0,1 °C
Oil temperature sensor
Air temperature
-20 °C – 100 °C
0,1 °C
Air temperature sensor
Fluid pressure
0 – 10000 hPa
10 hPa
Fluid pressure sensor,
Oil pressure sensor
1)
The measuring range is greater than the permissible measurement voltage