Solar
– –
Standard system
–
Menu for basic system component of solar thermal
system.
T1: Temperature of
collector group 1
80.0 °C
Temperature measured by collector temperature
sensor (T
1
).
T2: Temp at bottom of
solar cylinder
55.7 °C
Temperature measured by bottom cylinder
temperature sensor (T
2
) in solar cylinder.
SP: Collector grp 1 solar
pump status
Running | Off
Status of solar circuit pump (SP).
Collector group 1 shut
down
Yes | No
Shows whether safety shutdown of the solar circuit
pump (SP) due to overheating of the collectors (T
1
)
has occurred.
Solar cylinder status
Fully charged | Partially
charged
Charge status of solar cylinder.
SP: Coll grp 1 solar pump
running time
12463 h
Solar circuit pump (SP) hours run since
commissioning.
Thermal disinfection
1)
–
Menu for thermal disinfection part of the system.
PE: Therm disinfect
pump status
Running | Off
Status of thermal disinfection pump (PE).
Solar optimisation
3)
–
Menu for solar-assisted optimisation of conventional
heating system.
Solar yield in last hour
120 Wh
Solar energy yield in the last hour (a figure is only
shown if correct parameters have been set on the
solar optimisation menu,
Æ
chapter 8.5.3 on
page 62).
Solar yield today
2.38 kWh
Solar energy yield for the current day.
Solar yield overall
483.6 kWh
Total solar energy yield since commissioning.
DHW temperature
reduced by
4.7 K
Current reduction of the set DHW temperature
requested by the heating appliance as a result of the
available solar energy. Does not start until at least
30 days after commissioning.
Faults
40 Solar system
03 FR 100
EA heating appliance
...
List of current faults. More detailed information can
be displayed with
and
to confirm.
1) For FR 100 only with DHW cylinder on the appliance.
2) Only available if a name or telephone number has been registered at the contractor level.
3) Only available if the collector area has been set at the contractor level.
Menu structure INFO
Display (example)
Description