FlexiDome IP
Configuration via the browser | en
81
Bosch Security Systems
Operating Instructions
V 1.0 | 2006.12
7.14
Service Settings
7.14.1
Network
The settings on this page are used to integrate the unit into an
existing network.
–
Click
Set
after entering a new IP address.
–
To do this, enter the old IP address followed by
/
reset
(for instance
192.168.0.80/reset
) in the
address bar of your web browser. When the camera is
i
NOTICE!
Changes to the IP address, subnet mask or gateway address are
transferred to the unit by clicking
Set
. However, they do not
become active until the device is restarted.