6. Connect the two leads from a remote illuminator control device to terminals 5 and 6. This
connection is set to Normally Open (NO). When the connection is closed, the illuminator is
activated.
Note: The photocell controls the day/night switch operation, which prevents the Illuminator
turning on in daylight conditions.
9. Clean and grease the O-ring and threads before replacing the end cap. Refer to Installation
Overview, page 17.
10. Replace the end cap.
11. Tighten the end cap using the multi-use tool. Ensure that the O-ring is properly seated.
After tightening, ensure that there is no gap between the cap and the body of the housing.
12. Tighten the set screws on the end cap using the supplied hex key.
Set screws must not protrude from the threaded hole after tightening.
EX65 Explosion-Protected Illuminator
Connections | en
21
Bosch Security Systems
Installation Manual
2016.03 | 1.0 | F.01U.321.732