![Bosch EHP 6-11 LM User And Installation Manual Download Page 76](http://html.mh-extra.com/html/bosch/ehp-6-11-lm/ehp-6-11-lm_user-and-installation-manual_44188076.webp)
76
TECHNIC
AL INF
ORMA
TION
Technical information
Technical information single-phase models
Compress 3000
EHP7LW/M EHP9LW/M
11 LW/M
Emitted/ Supplied output at 0/35°C
1
kW
7.2/1.7
9.1/2.1
10.6/2.4
Emitted/ Supplied output at 0/50°C
2
kW
6.8/2.2
8.5/2.7
10.0/3.2
Minimum fl ow heating side
l/s
0.18
0.22
0.26
Nominal fl ow heating side
l/s
0.25
0.31
0.38
Maximum pressure available heating side (at nominal fl ow)
kPa
36
34
33
Nominal fl ow of antifreeze mixture to the collector hose
l/s
0.38
0.46
0.57
Maximum pressure available to collector hose (at nominal fl ow)
kPa
45
44
80
Type of antifreeze
Bioethanol - water or
Propylene/ethylene glycol - Water
Maximum pressure heating side
bars
1.5
Maximum pressure on collector hose side
bars
4
Maximum outgoing temperature to the heating system
°C
65
Working temperatures on collector hose side
°C
-5 to +20
Integrated collector hose and heat carrier pump
Yes
Power supply
230V 1N~ 50Hz
Additional heat settings
kW
3.0 / 6.0 / 9.0
The recommended type of fuse depends on the electrical output
3
6 kW electric cassette
9 kW electric cassette
AaM
40
50
50
AaM
63
63
63
Starting current. soft start
A
23.8
30.9
34.6
Compressor
Scroll
Type R407c HFC refrigerant
kg
1.60
1.80
2.40
Connection for heat fl uid out/in
mm
Cu 22
Cu 22
Cu 22
Out/in collector hose connection
mm
Cu 28
Cu 28
Cu 28
Dimensions of Model LW (LwDxH)
mm
600x600x1520
Weight of model LW
kg
152
155
170
Dimensions of Model LWM (LwDxH)
mm
600x600x1800
Weight of model LWM Hot water heater in stainless steel
kg
201
210
218
Integrated hot water heater with double shell on model LWM.
4
Stainless steel
Stainless steel
Stainless steel
Hot water heater model LWM
litres
185
185
185
Control unit
Rego 637
1
Output data at 0/35°C and min heating medium fl ow are stated according to the European standard EN 255.
2
Output data at 0/50°C and maccord. to clockeating medium fl ow are stated according to the European standard EN 255.
3
aM type fuse, D curve circuit breaker
4
Electric anode included
Summary of Contents for EHP 6-11 LM
Page 77: ...77 TECHNICAL INFORMATION ...
Page 78: ...78 TECHNICAL INFORMATION ...
Page 79: ...79 TECHNICAL INFORMATION ...