en
General information
20
:
Warning – Risk of electric shock!
■
Components inside the appliance may have
sharp edges. These may damage the
connecting cable. Do not kink or pinch the
connecting cable during installation.
Risk of electric shock!
■
It must always be possible to disconnect
the appliance from the electricity supply.
The appliance must only be connected to a
protective contact socket that has been
correctly installed.
The mains plug of the mains power cable
must be easily accessible after installation
of the appliance. If this is not possible, an
all-pole isolating switch must be integrated
into the permanent electrical installation
according to the conditions of overvoltage
category III and according to the installation
regulations.
The permanent electrical installation must
only be wired by a professional electrician.
We recommend installing a residual-current
circuit breaker (RCCB) in the appliance's
power supply circuit.
:
Warning – Risk of electric shock!
Incorrect repairs are dangerous. Repairs may
only be carried out and damaged power
cables replaced by one of our trained after-
sales technicians. If the appliance is defective,
unplug the appliance from the mains or switch
off the circuit breaker in the fuse box. Contact
the after-sales service.
:
Warning – Danger of suffocation!
Packaging material is dangerous to children.
Never allow children to play with packaging
material.
K
General information
General information
Checking the wall
■
The wall must be level, vertical and adequately load-
bearing.
■
The depth of the bore holes must be the same
length as the screws. The wall plugs must have a
secure grip.
■
The enclosed screws and wall plugs are suitable for
solid brickwork. Suitable fasteners must be used for
other structures (e.g. plasterboard, porous concrete,
poroton bricks).
■
The maximum weight of the extractor hood is
40
kg
.
Electrical connection
:
Warning – Risk of electric shock!
Components inside the appliance may have sharp
edges. These may damage the connecting cable. Do
not kink or pinch the connecting cable during
installation.
The required connection information can be found on
the rating plate on the top of the appliance.
Length of the cable: approx. 1.30
m
This appliance complies with the EC interference
suppression regulations.
:
Warning – Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.
The mains plug of the mains power cable must be
easily accessible after installation of the appliance. If
this is not possible, an all-pole isolating switch must be
integrated into the permanent electrical installation
according to the conditions of overvoltage category III
and according to the installation regulations.
The permanent electrical installation must only be wired
by a professional electrician. We recommend installing
a residual-current circuit breaker (RCCB) in the
appliance's power supply circuit.
Installation
en
21
5
Installation
Installation
Preparing for installation
Caution!
Ensure that there are no electrical wires, gas pipes or
water pipes in the area where holes are to be drilled.
If the extractor hood is to be operated in exhaust-air
mode, a flue duct must be fitted.
If the extractor hood is to be operated in air-recirculation
mode, an optional accessory must be fitted. To do this,
refer to the installation instructions provided. The flue
duct does not need to be fitted for air-recirculation
mode.
1.
Determine where the extractor hood should be
positioned and lightly mark where the lower edge of
the appliance should be on the wall. Determine
where the middle should be based on the hob.
Note:
We recommend fitting the extractor hood such
that the lower edge of the glass screen is in line with
the lower edges of the adjacent wall-hung cabinets.
Make sure that the specified safety clearances from
the hob are complied with.
2.
Place the template against the line drawn on the wall
and fasten it in place. Mark where the screws should
be inserted.
To fit the flue duct, the template must be cut along
the marked cut line.
3.
Drill 8
mm diameter holes to a depth of 80
mm for
fastening the appliance, remove the template and
press in the wall plugs flush with the wall.
$
%
]
]
[
PP
[
PP
[
PP
[
PP
\
\