background image

en

    Customer service

16

Accessories

(not included in the scope of delivery)

Note: 

These instructions apply to several appliance 

models. It may be the case that an optional accessory 

that is listed does not apply for your appliance.

Note: 

Observe the installation instructions in the 

accessory.

--------

Accessories

Order number

Starter set for air recirculation mode (flat hood 

with chimney)
Easy-change filter for starter set

DWZ0AF0U0

DWZ0AF0A0

Starter set for air recirculation mode (flat hood 

without chimney)
Easy-change filter for starter set

DWZ0AF0T0

DWZ0AF0A0

Starter set for air recirculation mode (angled hood 

with chimney)
Easy-change filter for starter set

DWZ0AK0U0

DWZ0AK0A0

Starter set for air recirculation mode (angled hood 

without chimney)
Easy-change filter for starter set

DWZ0AK0T0

DWZ0AK0A0

Starter set for air recirculation mode with filter 

that can be regenerated (flat hood with chimney)

DWZ0AF0S0

Starter set for air recirculation mode with filter 

that can be regenerated (flat hood without chim-

ney)

DWZ0AF0R0

Starter set for air recirculation mode with filter 

that can be regenerated (angled hood with chim-

ney)

DWZ0AK0S0

Starter set for air recirculation mode with filter 

that can be regenerated (angled hood without 

chimney)

DWZ0AK0R0

CleanAir air recirculation module
Easy-change filter for CleanAir air recirculation 

module (cannot be regenerated)

DWZ1AX5C6
DZZ1XX1B6

Easy-change filter for CleanAir air recirculation 

module (can be regenerated)

DZZ0XX0P0

Installation instructions    

en

17

INSTALLATION INSTRUCTIONS

Installation instructions

Installation instructions

This appliance is installed on the wall.

If the extractor hood is to be operated in exhaust-air 

mode, a flue duct must be fitted. 

If the extractor hood is to be operated in air-

recirculation mode, an optional accessory must be 

fitted. To do this, refer to the installation instructions 

provided.The flue duct does not need to be fitted for 

air-recirculation mode.

For additional optional accessories, refer to the 

installation instructions provided.

The surfaces of the appliance are sensitive. Avoid 

damaging them during installation. 

$

%

$ %

$

PLQ

PP

PLQ PP

PD[PP

PLQ

PP

PLQ

PP

PLQ

PP

PLQ PP

PD[PP

•PP

•PP

%

•PP

•PP

PP

PP

Summary of Contents for DWK98PR60/02

Page 1: ...3FHJTUFS ZPVS OFX EFWJDF PO Z PTDI OPX BOE HFU GSFF CFOFGJUT CPTDI IPNF DPN XFMDPNF en Instructions for installation and use Extractor hood ...

Page 2: ...s installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appli...

Page 3: ...In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the grease filter may catch fire Regularly clean the grease filter Neve...

Page 4: ... are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes o...

Page 5: ...onmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible...

Page 6: ... Intermediate position for the glass front On some appliances the glass front can be adjusted to an intermediate position The intermediate position can be used for eliminating particularly strong cooking smells and large amounts of steam Take hold of the glass front in the centre and open it carefully Fan run on time Switching on Touch the y symbol The fan will run at fan setting 1 After approxima...

Page 7: ... are flashing To do this touch the symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched off Touch and hold the D symbol Touch the 2 symbol Take your finger off the D symbol This will switch the electronic controller over to air recirculation mode filters ...

Page 8: ...uch the symbol The fan will start at setting 2 2 Touch the symbol The optimum fan setting is set automatically using the PerfectAir sensor Switching off Touch or any fan setting to switch off automatic mode The fan switches itself off automatically if the PerfectAir sensor detects no further change in the air quality in the room Automatic mode can run for a maximum of 4 hours Sensor control In aut...

Page 9: ...will switch the electronic controller over to air recirculation mode filters that can be regenerated Repeatedly touching and holding the D symbol and touching the 1 symbol switches the electronic controller back over to air extraction mode Decorative LED lighting The decorative LED lighting can be switched on and off independently of the fan Touch the l symbol Setting the brightness Press and hold...

Page 10: ...liance via the hood controls on the hob If the extractor hood is being operated by means of the controls on the hood itself this mode of operation always has priority It is not possible to use the hood controls on the hob during this time Setting up a connection The hood must be switched off before you can connect the hob and extractor hood Connecting directly Make sure that the hob is switched on...

Page 11: ... the process at any time by pressing the symbol To connect the extractor hood to your home network the hood and the light must be switched off 1 Press and hold the D symbol until it starts to flash 2 Press 1 to start automatic login to your home network The LED for fan setting 1 and the D symbol will flash 3 Press the WPS button on the router within the next 2 minutes If the extractor hood has suc...

Page 12: ...set the connections you have saved on your home network and on Home Connect at any time Press and hold the and D symbols until the D symbol goes out When the audible signal is switched on an audible signal sounds About data protection When your appliance is connected for the first time to a WLAN network which is connected to the Internet your appliance transmits the following categories of data to...

Page 13: ...Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the glass front slowly and fully Hold the glass front in the centre when doing so gripping it firmly 2 Open the lock and swing down the metal grease filter When you do this take hold of the metal grease filter from underneath with your ...

Page 14: ...nse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Place ...

Page 15: ... appliance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed custom...

Page 16: ...ilter for starter set DWZ0AK0U0 DWZ0AK0A0 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set DWZ0AK0T0 DWZ0AK0A0 Starter set for air recirculation mode with filter that can be regenerated flat hood with chimney DWZ0AF0S0 Starter set for air recirculation mode with filter that can be regenerated flat hood without chim ney DWZ0AF0R0 Starter set for ...

Page 17: ... hood is to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them during installation PLQ PP PLQ PP PD P...

Page 18: ...tion location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the grease filter may catch fire The speci...

Page 19: ...al vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire...

Page 20: ...l KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks The max...

Page 21: ...hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety clearances from the hob are complied with 2 Place ...

Page 22: ...hout a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Page 23: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Warning Risk of electric shock Components inside the appliance may have sharp edges These may d...

Page 24: ...N XFMDPNF PPLJOH GPS IFMQ PV MM GJOE JU IFSF YQFSU BEWJDF GPS ZPVS PTDI IPNF BQQMJBODFT OFFE IFMQ XJUI QSPCMFNT PS B SFQBJS GSPN PTDI FYQFSUT JOE PVU FWFSZUIJOH BCPVU UIF NBOZ XBZT PTDI DBO TVQQPSU ZPV XXX CPTDI IPNF DPN TFSWJDF POUBDU EBUB PG BMM DPVOUSJFT BSF MJTUFE JO UIF BUUBDIFE TFSWJDF EJSFDUPSZ 3PCFSU PTDI BVTHFSÉUF NC BSM 8FSZ 4USB F ßODIFO FSNBOZ XXX CPTDI IPNF DPN 9001159153 9001159153 9...