background image

Imp

ort

Ap

plia

nce

s.c

om

THE EASIEST WAY TO SELF-IMPORT APPLIANCES DIRECT FROM EUROPE.

en

    Customer service

12

4

Customer service

Customer service

When calling us, please quote the product number 

(E no.) and the production number (FD no.) so that we 

can provide you with the correct advice. These numbers 

can be found on the rating plate on the top of the 

appliance.

You can make a note of the numbers of your appliance 

and the telephone number of the after-sales service in 

the space below to save time should it be required.

Please be aware that a visit by an after-sales engineer 

will be charged if a problem turns out to be the result of 

operator error, even during the warranty period.
Please find the contact data of all countries in the 

enclosed customer service list.

To book an engineer visit and product advice

Rely on the professionalism of the manufacturer. You 

can therefore be sure that the repair is carried out by 

trained service technicians who carry original spare 

parts for your appliances.

Accessories

(not included in the scope of delivery)

Note: 

These instructions apply to several appliance 

models. It may be the case that an optional accessory 

that is listed does not apply for your appliance.

Note: 

Observe the installation instructions in the 

accessory.

--------

E no.

FD no.

After-sales service

O

GB

0344 892 8979 

Calls charged at local or mobile rate.

IE

01450 2655 

0.03 € per minute at peak. Off peak 0.0088 € 

per minute.

Z-Nr:

FD:

E-Nr:

Type:

Accessories

Order number

Starter set for air recirculation mode (flat hood 

with chimney)
Easy-change filter for starter set

DWZ0AF0U0

DWZ0AF0A0

Starter set for air recirculation mode (flat hood 

without chimney)
Easy-change filter for starter set

DWZ0AF0T0

DWZ0AF0A0

Starter set for air recirculation mode (angled hood 

with chimney)
Easy-change filter for starter set

DWZ0AK0U0

DWZ0AK0A0

Starter set for air recirculation mode (angled hood 

without chimney)
Easy-change filter for starter set

DWZ0AK0T0

DWZ0AK0A0

Starter set for air recirculation mode with filter 

that can be regenerated (flat hood with chimney)

DWZ0AF0S0

Starter set for air recirculation mode with filter 

that can be regenerated (flat hood without chim-

ney)

DWZ0AF0R0

Starter set for air recirculation mode with filter 

that can be regenerated (angled hood with chim-

ney)

DWZ0AK0S0

Starter set for air recirculation mode with filter 

that can be regenerated (angled hood without 

chimney)

DWZ0AK0R0

CleanAir air recirculation module
Easy-change filter for CleanAir air recirculation 

module (cannot be regenerated)

DWZ0AX5C0

DSZ5201

Easy-change filter for CleanAir air recirculation 

module (can be regenerated)

DZZ0XX0P0

Summary of Contents for DWK97JQ60

Page 1: ...OM EUROPE Thanks for choosing ImportAppliances for your kitchen appliance purchase We hope you are enjoying the convenience quality and affordability of your new appliance If you have any issues or questions please contact us via email info ImportAppliances com User Manual ...

Page 2: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE en Instructions for installation and use Extractor hood ...

Page 3: ...rks perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above s...

Page 4: ... cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode War...

Page 5: ...he circuit breaker in the fuse box Contact the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric s...

Page 6: ...vironmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsi...

Page 7: ...xtractor hood automatically switches back to fan setting 3 Switching off If you want to end intensive mode before the preset time expires touch the symbol for the required fan setting Intermediate position for the glass front On some appliances the glass front can be adjusted to an intermediate position The intermediate position can be used for eliminating particularly strong cooking smells and la...

Page 8: ...e switched over accordingly The extractor hood must be connected and switched off Touch and hold the D symbol Touch the 2 symbol Take your finger off the D symbol This will switch the electronic controller over to air recirculation mode filters that cannot be regenerated Touch and hold the D symbol Touch the 3 symbol Take your finger off the D symbol This will switch the electronic controller over...

Page 9: ... off Touch the y symbol This immediately stops fan run on Automatic mode Switching on 1 Touch the symbol The fan will start at setting 2 2 Touch the symbol The optimum fan setting is set automatically using a sensor Switching off Press the or button to switch off automatic mode The fan switches itself off automatically if the sensor detects no further change in the air quality in the room Automati...

Page 10: ...udible signal Switching on Touch and hold the and y symbols at the same time for approximately 3 seconds when the fan is switched off An audible signal will sound as an acknowledgement Switching off Touch and hold the and y symbols at the same time for approximately 3 seconds when the fan is switched off An audible signal will sound as an acknowledgement 2Cleaning and maintenance Cleaningandmainte...

Page 11: ...Soak the metal grease filters in hot soapy water Clean the filters with a brush and then rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashin...

Page 12: ...only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualified technician electrician only ...

Page 13: ...ote Observe the installation instructions in the accessory E no FD no After sales serviceO GB 0344 892 8979 Calls charged at local or mobile rate IE 01450 2655 0 03 per minute at peak Off peak 0 0088 per minute Z Nr FD E Nr Type Accessories Order number Starter set for air recirculation mode flat hood with chimney Easy change filter for starter set DWZ0AF0U0 DWZ0AF0A0 Starter set for air recircula...

Page 14: ... fitted If the extractor hood is to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them during install...

Page 15: ...pliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the...

Page 16: ...operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Swee...

Page 17: ...w children to play with packaging material KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboa...

Page 18: ...ion mode 1 Determine where the extractor hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety clearance...

Page 19: ...n 18 Fitting with a flue duct Fitting without a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Page 20: ...ctor 3 Use suitable means to seal both joints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Warning Risk of electric shock Components inside the a...

Page 21: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 970606 9001160137 9001160137 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...

Reviews: