13
en
Connection in Ducting Version
When installing the ducting version, connect the
hood to the chimney using either a flexible or rigid
pipe ø 150 or 120 mm, the choice of which is left to
the installer.
To install a ø 120 mm air exhaust connection,
insert the reducer flange
9
on the hood body
outlet.
Installation
�����
�
�����
Fix the pipe in position using sufficient pipe
clamps (not supplied).
Remove charcoal filters, if present.
Connection in Recirculation Version
without chimney:
For the recirculation version without chim-
ney, only the charcoal is additionally required.
Please call customer service to order the char-
coal filter.
Screw the filter cover
16
onto the air outlet, us-
ing four screws
12c
supplied.
Fix the directional grille
8
on the filter cover air
outlet using the 2 screws
12d
provided.
Ensure that the activated charcoal filters have
been inserted. (see parag. “Activated carbon
filter” in Filters and Maintenance chapter)
���
��
�����
����
��
with chimney:
All the items named in this procedure are
included in the recirculation kit. The correspond-
ing accessory numbers can be found at the end
of these operating instructions.
Put connection
15
into the connection support
7.3
.
Insert the connection extension pieces laterally
14.1
in connection
15
.
Make sure that the outlet of the extension
pieces
14.1
is horizontally and vertically aligned
with the chimney outlets.
Connect the air outlet connection
15
to the
hood body outlet using either a pipe ø 150 mm.
��
���
���
�
Use the jubilee clips
25
to ensure a fix connec-
tion between pipe and hood outlet and between
pipe and connection (
15
).
Ensure that the activated charcoal filters have
been inserted.(see parag. “Activated carbon
filter” in Filters and Maintenance chapter)