background image

12

en

Electrical connection

Electrical data:

Are to be found on the name plate inside the appli-

ance after removal of the filterframe.

 

Before undertaking any repairs,

 always 

disconnect the extractor hood from the electricity 

supply.

Length of the connecting cable: 1.30 m.

This extractor hood corresponds to EC regulations 

concerning RF interference suppression.

Installation

This extractor hood

 is intended to be mounted 

onto the kitchen wall.

1.  Unhook the filter-holding Grid (see “Removing 

and inserting metal self- supporting grease 

filters

”)

2.  Draw a line on the wall from the ceiling to the 

lower edge of the hood at the centre of the lo-

cation where the hood is going to be mounted.

3.  Use the template or following the picture to 

mark the points (

A-B-C

) on the wall where the 

screws will be mounted.

����������������������

���

���

����������������

���

��

���

���

���

�����

�����

���

���

���

��

���

 

Ensure that the minimum distance between the 

hob and the extractor hood is maintained – 

400 mm

 

for the electric or gas hob.

4.  Drill ø 12 mm holes 

A

 and ø 8 mm holes 

for 

the extractor hood. Drill ø 8 mm holes 

C

 for the 

chimney brackets (only if you think to install the 

chimney).

5.  Insert bracket plugs 

11a 

into the holes 

A

 and 

screw into place.

6.  Insert plugs 

11

 into the holes 

B

 and 

C

 so that 

they are flush with the wall.

7.  Fix the brackets 

7.2.1

 using the 

12a 

screws 

supplied (only if you think to install the chim-

(only if you think to install the chim-

ney).

 

 

In case of hood installation in recirculation 

version with the chimney, the upper bracket 

7.2.1

 must be fixed together with the Air Outlet 

Connection Support 

7.3

.

Mounting the hood body

8.  Adjust the two screws 

Vr

, on brackets 

11a

, to a 

minimum.

9.  Hook the hood canopy onto the two brackets 

11a.

10.  From inside the hood canopy, adjust the screws 

Vr 

to set the Hood Canopy level.

Installation

Note:

 Take into account any special accessories 

that are going to be fitted.

��

���

11.  Tighten the safety screw 

11

 in holes 

B

.

Summary of Contents for DWK096651B

Page 1: ...Internet http www bosch hausgeraete de Bosch Info Team de Tel 01 80 5 30 40 50 E 0 14 Min DTAG DWK096651B en Operating and installation instructions ...

Page 2: ......

Page 3: ...en conveyed back into the kitchen The grease filter absorbs the grease particles in the kitchen vapours The activated carbon filter binds the odorous substances If no activated carbon filter is installed it is not possible to bind the odorous substances in the cooking vapours Lighting Light fan switches Filter grille Chimney Operating modes Exhaust air mode The extractor hood fan extracts the kitc...

Page 4: ...ood is situated over a gas hob operate the hood at maximum setting if three or more gas hotplates are operated simultaneously Safety instructions Do not flambé food directly under the extractor hood Risk of grease filter catching fire due to flames The hotplates must always be covered with a utensil Restrictions apply to the use of the extractor hood over a solid fuel burner coal wood etc See Inst...

Page 5: ...t shows H E By pressing this key it is possible to set the delayed shutdown of the appliance to 30 minutes This function is suitable for a complete elimination of the residual smells It can be activated at any position and it is deac tivated by pressing the key again or by switching off the motor The point low to right flashes F With a short press turns light on and off With an extended press turn...

Page 6: ...etal mesh filters are used to trap the grease particles in the cooking vapours The filter mats are made from noncombustible metal Caution As the filter becomes more and more saturated with grease there is an increased risk of fire and the function of the extractor hood may be impaired Important By cleaning the metal grease filters at appropriate intervals the possibility of them catching fire as a...

Page 7: ...en restoring the connection press and hold B key When releasing the key two rotating rectangles appear on the display Within 3 seconds press the B key until a flash ing confirmation appears on the dispaly 2 flashes with C sign charcoal filter satu ration alarm ACTIVATED 1 flash with C sign charcoal filter satura tion alarm DEACTIVATED Filters and maintenance Replacing the activated carbon filter R...

Page 8: ...aning agent Do not use aggressive acidic or caustic clean ers Do not use abrasive agents Replacing the light bulbs 1 Switch off the extractor hood and pull out the mains plug or switch off the electricity supply at the fuse box When switched on the halogen bulbs become very hot Even for some time after the bulbs have been switched off there is still a risk of burns 2 With the aid of a screwdriver ...

Page 9: ...pliance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environ mentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local au thority about current means of disposal The extractor hood can be used in...

Page 10: ...an be achieved if combustion air can flow through non lockable openings e g in doors win dows and via the airintake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting...

Page 11: ... the terminal in the plug marked E or with the symbol or coloured green or green and yel low 2 Connect the blue Neutral wire to the terminal in the plug marked N or coloured black 3 Connect the brown Live wire to the terminal marked L or coloured red The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations If possible site the earth...

Page 12: ... the minimum distance between the hob and the extractor hood is maintained 400 mm for the electric or gas hob 4 Drill ø 12 mm holes A and ø 8 mm holes B for the extractor hood Drill ø 8 mm holes C for the chimney brackets only if you think to install the chimney 5 Insert bracket plugs 11a into the holes A and screw into place 6 Insert plugs 11 into the holes B and C so that they are flush with the...

Page 13: ...cover air outlet using the 2 screws 12d provided Ensure that the activated charcoal filters have been inserted see parag Activated carbon filter in Filters and Maintenance chapter with chimney All the items named in this procedure are included in the recirculation kit The correspond ing accessory numbers can be found at the end of these operating instructions Put connection 15 into the connection ...

Page 14: ...ehind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c supplied Make sure that the outlet of the extensions pieces is aligned with the chimney outlets Lower Chimney Slightly widen the two sides of the Chimney and hook them between the upper Chimney and the wall making sure that they are well seated Fix the lower part laterally to the ...

Page 15: ...DHZ5455 ...

Page 16: ...Robert Bosch Hausgeräte GmbH 436004609_01 090218 ...

Reviews: