DSA E-Series (E2800 12-bay)
Turning on/off AC power | en
23
Bosch Sicherheitssysteme GmbH
Quick Installation Guide
2017.12 | V1 | DOC
6
Turning on/off AC power
6.1
Turning on AC power
Make sure the Ethernet cable is connected to the management host. The default IP addresses
will take three minutes to initialize from the time the network is attached.
The default IP addresses are:
–
Controller A, Port 1: 192.168.128.101
–
Controller B, Port 1: 192.168.128.102
Notice!
DHCP is attempted for the first three minutes of attaching the network cables. If a DHCP
lease was not offered within this time, the controllers will use the default addresses.
To turn on power to the controller unit or the expansion units:
1.
Connect the cabinet to the power supply.
2.
Turn on the power distribution units of the cabinet.
3.
If you have expansion units, turn on their two power switches first.
Note:
Wait for 2
minutes to allow hard disks to spin up before applying power to the
controller unit.
4.
Turn on the two power switches on the controller unit and wait approximately 3
minutes.
Note:
–
The default IP addresses will take approximately 3
minutes to initialize from the time
the network is attached.
–
Do not turn off the power switches during the power-on process.
–
The fans are very loud when they first start up. The loud noise during start-up is
normal.
5.
Check the LEDs and the seven-segment display on the back of each controller.
Note:
The seven-segment display shows a repeating sequence (OS, Sd, blank) to indicate
that the controller is performing start-of-day processing. After the controller has started,
the display shows the tray ID.
6.
If any of the amber LEDs are on, there might be a problem with a component. Confirm
you completed the installation steps correctly. If you are unable to resolve the problem,
contact your local Bosch Technical Support team.
7.
Connect all cables if required.
8.
Start recording of the cameras.
6.2
Turning off AC power
We recommend turning off the system when moving the system to another location and
upgrading or replacing the hardware, for example.
To turn off power to the controller unit or the expansion units:
1.
Stop recording of the cameras and wait for 5
minutes.
2.
Ensure there are no background operations in progress.
3.
Turn off the controller-unit and wait that all LEDs are off.
4.
Turn off the expansion units and wait for 2
minutes to allow hard disks to spin down.
5.
Disconnect the cables if required.