background image

16

en | Connection

DSA E-Series (E2800 12-bay)

2017.12 | V1 | DOC

Quick Installation Guide

Bosch Sicherheitssysteme GmbH

5

Connection

5.1

Connecting the expansion units

The expansion units are shipped with the appropriate number of SAS cables.
To connect the components:

4

Connect the SAS cable from the SAS port on the controller unit to the SAS port on the
expansion unit.

One expansion unit - single controller configuration

Controller A

IOM B

IOM A

One expansion unit - dual controller configuration

(recommended cabling for maximum throughput)

Controller B

Controller A

IOM B

IOM A

Three expansion units - dual controller configuration

Controller B

Controller A

IOM B

IOM A

IOM B

IOM A

IOM B

IOM A

Summary of Contents for DSA-N2C8X4-12AT

Page 1: ...bay DSA N2E8X4 12AT DSX N1D8X4 12AT DSA N2C8X4 12AT DSA N2E8X8 12AT DSX N1D8X8 12AT DSA N2C8X8 12AT DSA N2E8XA 12AT DSX N1D8XA 12AT DSA N2C8XA 12AT DSA N2E8XC 12AT DSX N1D8XC 12AT DSA N2C8XC 12AT en Quick Installation Guide ...

Page 2: ......

Page 3: ...2 Additional equipment 9 2 3 Additional documentation 9 3 Device views 10 4 Installation 13 4 1 Installing a 2U 12 bay unit 13 4 2 Installing the front bezel and end caps 15 5 Connection 16 5 1 Connecting the expansion units 16 5 2 Connecting the controller unit to the network 18 5 3 Connecting the controller unit to the management hosts 18 5 4 Connecting the units to the power supply 19 5 5 Suppo...

Page 4: ...nings before operating the device Unplug the unit from the outlet before cleaning Follow any instructions provided with the unit Clean only with a dry cloth Do not use liquid cleaners or aerosol cleaners Do not install device near any heat sources such as radiators heaters stoves or other equipment including amplifiers that produce heat Never spill liquid of any kind on the device Take precautions...

Page 5: ...ous voltage or other hazards Refer all servicing to qualified service personnel Be sure the service technician uses replacement parts specified by the manufacturer Unauthorized substitutions could void the warranty and cause fire electrical shock or other hazards Safety checks should be performed upon completion of service or repairs to the unit to ensure proper operating condition Observe the rel...

Page 6: ...r structural damage never turn on the power to the equipment Risk of electrical shock Before removing or installing a power supply turn off the power switch and unplug the power cord Pinching hazard As you push the canister into the slot ensure that your fingers are not pinched between the lever and the canister The lever automatically moves toward the closed position as the canister is pushed int...

Page 7: ...ver because you might be exposed to laser radiation 1 5 Caution notices Caution The battery used in this device might present a risk of fire explosion or chemical burn if mistreated DO NOT crush or puncture short circuit external contacts disassemble dispose of in fire or water heat above maximum temperature limit or incinerate Caution DOUBLE POLE NEUTRAL FUSING Caution To avoid personal injury be...

Page 8: ...k the poles Caution Battery replacement For qualified service personnel only A lithium battery is located inside the unit enclosure To avoid danger of explosion replace the battery as per instructions Replace only with the same or equivalent type recommended by the manufacturer Dispose of the replaced battery in an environmentally friendly way and not with other solid waste Refer all servicing to ...

Page 9: ...esk STService de bosch com The registration form is available as part of the shipment in paper format and on the Bosch web site 2 2 Additional equipment You may need the following equipment A Phillips No 2 and a medium flat blade screwdriver An ESD wrist strap An Ethernet switch or network hub Ethernet cables Management station or personal computer 2 3 Additional documentation For warnings and det...

Page 10: ...1 5 9 2 6 3 7 4 8 14 10 11 12 13 1 Controller canister 2 Channel 3 left Channel 4 right Host interface ports Dual 10 GB iSCSI optical Note Use only RJ45 Base T ports or optical ports 3 Management port 1 left Management port 2 right Dual 1 Gigabit Ethernet Note Use only Port 1 per controller default 4 Serial port RJ45 5 Serial port mini USB 6 USB port only for factory use 7 Dual 12 Gb SAS drive exp...

Page 11: ... ports 3 Management port 1 left Management port 2 right Dual 1 Gigabit Ethernet Note Use only Port 1 per controller default 4 Serial port RJ45 5 Serial port mini USB 6 USB port only for factory use 7 Dual 12 Gb SAS drive expansion ports 8 Controller B see Controller A 9 Status display 10 Channel 5 left Channel 6 right Host interface ports Dual 10 GB iSCSI RJ45 Base T Note Use only RJ45 Base T port...

Page 12: ... GmbH 1 IOM A 2 IOM A SAS port 1 3 IOM A SAS port 2 4 IOM A SAS port 3 5 IOM A SAS port 4 6 IOM B 7 IOM B SAS port 1 8 IOM B SAS port 2 9 IOM B SAS port 3 10 IOM B SAS port 4 11 Power fan canister 1 12 On off switch 13 Mains connection 100 240 VAC 14 Power fan canister 2 See also Supported connections page 20 ...

Page 13: ...ced above and below the controller unit To install a 12 bay controller or expansion unit 1 Determine where you want to install the unit in the rack or system cabinet Note Whenever possible install the units from the bottom of the rack up so that you can use the units underneath as a guide for installing the next set of rails 2 Attach the rails to the rack or system cabinet as follows Place the rai...

Page 14: ...o secure the unit to the rack post Replace the end caps or bezel when you are done Note You might need to adjust the rails to ensure that the unit slides all the way onto the rails Note Do not place additional equipment on the rails after you finish installing the unit The rails are not designed to bear additional weight 5 Secure the unit to the front of the rack or system cabinet and rails by ins...

Page 15: ...tion of the cabinet 4 2 Installing the front bezel and end caps A front bezel covers the front of the controller unit and the expansion unit while left and right end caps cover the mounting flanges on each unit To install the front bezel 1 Position the front bezel in front of the controller unit or the expansion unit so that the holes at each end align with the fasteners on the unit 2 Snap the bez...

Page 16: ...nect the components 4 Connect the SAS cable from the SAS port on the controller unit to the SAS port on the expansion unit One expansion unit single controller configuration Controller A IOM B IOM A One expansion unit dual controller configuration recommended cabling for maximum throughput Controller B Controller A IOM B IOM A Three expansion units dual controller configuration Controller B Contro...

Page 17: ...uide 2017 12 V1 DOC Maximum configuration dual controller configuration Controller B Controller A IOM B IOM A IOM B IOM A IOM B IOM A IOM B IOM A IOM B IOM A IOM B IOM A IOM B IOM A Notice You can connect a 12 bay DSA E2800 controller unit to a maximum of seven 12 bay DSA E2800 expansion units ...

Page 18: ...the controller unit and the relevant IP camera ports are in the same range on the switch Switch topology 2 3 1 Switch 1 Switch 2 Controller A iSCSI host interface ports RJ45 Base T Note Optionally use the optical host interface ports 3 Controller B iSCSI host ports RJ45 Base T Note Optionally use the optical host interface ports 5 3 Connecting the controller unit to the management hosts The manage...

Page 19: ...te Used as default 9 Management port 2 Ethernet Note Reserved for maintenance operations if the hardware contains a second Ethernet port Notice Ethernet port 2 should be reserved for maintenance operations if your hardware contains a second Ethernet port 5 4 Connecting the units to the power supply To connect the controller unit and the expansion units to the power supply 1 Confirm that the two po...

Page 20: ...e approximately 3 minutes to initialize from the time the network is attached Do not turn off the power switches during the power on process The fans are very loud when they first start up The loud noise during start up is normal 5 Check the LEDs and the seven segment display on the back of each controller Note The seven segment display shows a repeating sequence OS Sd blank to indicate that the c...

Page 21: ... optical 5 Channel 5 iSCSI RJ45 Base T 6 Channel 6 iSCSI RJ45 Base T Single controller units support 2 different cabling options for the iSCSI ports Default iSCSI RJ45 Base T Alternatively iSCSI optical 12 bay dual controller unit LN K LN K P1 P2 0b 0a e0c e0d LN K LN K P1 P2 0b 0a e0c e0d LN K LN K P1 P2 0b 0a e0c e0d LN K LN K P1 P2 0b 0a e0c e0d Controller B Controller A 1 2 3 4 5 6 1 2 3 4 5 6...

Page 22: ...ing feature is enabled on dual controller units by default Dual controller units support 2 different cabling options for the iSCSI ports Default iSCSI RJ45 Base T Note Channel 5 Controller B is the fallback of Channel 5 Controller A and Channel 6 Controller A is the fallback of Channel 6 Controller B Alternatively iSCSI optical Note Channel 3 Controller B is the fallback of Channel 3 Controller A ...

Page 23: ...3 minutes to initialize from the time the network is attached Do not turn off the power switches during the power on process The fans are very loud when they first start up The loud noise during start up is normal 5 Check the LEDs and the seven segment display on the back of each controller Note The seven segment display shows a repeating sequence OS Sd blank to indicate that the controller is per...

Page 24: ...lling and configuring the storage array For the basic setup use the Video Recording Manager Configuration Manager software For detailed information in Configuration Manager refer to the Video Recording Manager Help More information For more information software downloads and documentation visit www boschsecurity com and go to the respective product page ...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2017 ...

Reviews: