Installation Instructions

DS794Z Long Range Passive Infrared

Intrusion Detector with Self-test

Trademark names are used throughout this document. In most cases,
these designations are claimed as trademarks or registered trademarks in
one or more countries by their respective owners. Rather than placing a
trademark symbol in every occurrence of a trademark name, Bosch
Security Systems, Inc. (hereinafter referred to as Bosch) uses the
names only in an editorial fashion and to the benefit of the trademark

owner with no intention of infringing the trademark.

1.0 General Description

The DS794Z is a high performance intrusion detector designed to
provide an alarm condition upon the detection of an intruder moving
into or through its coverage pattern.

Technology designed into the DS794Z is based on the transmission
of infrared energy; all objects transmit infrared energy. The warmer an
object is, the more infrared energy transmitted. The DS794Z detects
the change in infrared energy that occurs when a target passes
through its view.

The coverage pattern, consisting of sensor fingers (to detect the
target) is arranged in a side-by-side array. The total number of fingers
is determined by the optical module used. The fingers are grouped
by polarity into pairs, with each pair consisting of one zone.

To detect motion, the DS794Z must first see a change in infrared
energy in one finger followed by a change of energy in the remaining
finger. Therefore, disturbances that occur in only one finger do not
constitute motion and are ignored.

The “catch sensitivity” may be changed by the installer to provide a
degree of sensitivity determined by each installation.

2.0 Specifications

Coverage:

The DS794Z is shipped with the OA80 80 foot (24.4 m) Mirror installed.
If a 200 foot (61 m) range is desired, it will be necessary to install the
OA200 Mirror that is sent along with the unit.

Standard Range:

Broad (OA80 Mirror):

80 ft. by 50 ft. (24.4 m by 15.3 m)

Long (OA200 Mirror):

200 ft. by 10 ft. (61.0 m by 3.1 m)

Optional Range:

Long (OA120 Mirror):

120 ft. by 25 ft. (36.6 m by 7.6 m)

Input Power:

   6.0  to 15.0 VDC; 18 mA at 12 VDC.

Standby Power:

  There is no internal standby battery. Connect to

DC power sources capable of supplying standby power if primary
power fails. Eighteen mA-H required for each hour of standby time
needed. 

Four hours (72 mA-H minimum) are required for UL  Listed

Requirements.

Sensitivity:

  Field selectable for Standard, Intermediate, or High.

Alarm Relay:

  Silent operating Form “C” relay. Contacts rated 125

mA, 28 VDC maximum for DC resistive loads. 

Do not use with

capacitive or inductive loads.

Tamper:

  Normally Closed (with cover in place) tamper switch.

Contacts rated at 28 VDC, 125 mA maximum.

Trouble Output:

  A solid state open collector shorts to ground (-)

when the detector is in a trouble condition. Maximum current load
is 25 mA.

Temperature:

  The storage and operating range is -20° to +120°F

(-29° to +49°C). 

For UL Listed Requirements, the range is +32° to

+120°F (0° to +49°C).

Sonalert

 

Connector: 

 Using a Sonalert  type sounder (low voltage)

will provide an audible tone when the unit is in alarm. 

A sounder is

intended only as an aid for walk testing during installation.

•  

Reading Bosch Security Systems, Inc. Product Date Codes

For Product Date Code information, refer to the Bosch Security
Systems, Inc. Web site at: 

http://www.boschsecurity.com/datecodes/

Front view with cover off

TERMINAL

STRIP

SETUP SWITCH BANK

(UNDER MIRROR ASSEMBLY)

SONALERT™ CONNECTOR

(UNDER MIRROR ASSEMBLY)

COVER TAMPER SWITCH

CIRCUIT BOARD RETAINER TAB (2)

WALK TEST/ALARM

LED INDICATOR

8

7

6

5

4

REPLACEABLE

OPTICAL MODULE

PERMANENT

RELFECTING MIRROR

BACKGROUND NOISE

VOLTAGE CONNECTOR

TAMPER RELAY

TO REPLACE OPTICAL MODULE,

LIFT THIS EDGE UP

REAR WIRE

ENTRANCE

REAR WIRE

ENTRANCE

SURFACE WIRE

ENTRANCE

BRACKET WIRE ENTRANCE

CORNER MOUNT

HOLES (4)

SURFACE MOUNT

HOLES (4)

COVER TABS (4)

TAMPER SCREW

HOLE

TEST/SOUNDER

CORD SLOT

Base

Options: 

 OA120-2* Mirror and TC6000 Test Cord.

* Shipped in packages of 2.

3.0 Mounting

Select a location likely to intercept an intruder moving 

across

 the

coverage pattern (review patterns on page 4). 

The recommended

mounting height is 7.5 ft. (2.3 m) for the DS794Z with the OA80 or
OA120 Mirror, or 10 ft. (3.1 m) for the OA200 Mirror.

 Each mounting

surface should be solid and vibration free. When mounting, avoid hot
and cold drafts, heat sources, animals and pets and direct sunlight.
Do not mount outdoors.

• Remove the cover by inserting a thin screwdriver into each of the four

slots on the cover. Twist gently until the cover snaps free of the tabs
on the base.

Summary of Contents for DS794Z

Page 1: ...ct to DC power sources capable of supplying standby power if primary power fails Eighteen mA H required for each hour of standby time needed Four hours 72 mA H minimum are required for UL Listed Requirements Sensitivity Field selectable for Standard Intermediate or High Alarm Relay Silent operating Form C relay Contacts rated 125 mA 28 VDC maximum for DC resistive loads Do not use with capacitive ...

Page 2: ...sher and hex nut see drawing Hand tighten the hex nut Thread the bracket wiring through the stud and along the wiring channel in the detector s base to the area of the circuit board s terminal strip Return the circuit board to its base Slide the back of the circuit board under the tabs at the back of the base then snap the front into place Aim the detector in the desired general direction and tigh...

Page 3: ...rvision trouble once per secondusingcodedpulses Thesupervisiontroublesignalactivates the Trouble Output available on terminal 8 The supervision features function as follows PIR TheoperationofthePIRiselectronicallycheckedapproximately every 12 hours If the PIR fails the Alarm Test LED will flash 4 times and the Trouble Output will activate Motion Monitor Supervision This feature verifies that the d...

Page 4: ...ndicator is not desired after setup and walk tests are completed place configuration switch S1 in the Off position 9 2 Sealing the Wire Entrance The foam plug that is provided with the unit is for sealing the wire entrance from drafts and insects 9 3 Maintenance At least once a year the range and coverage should be checked according to Sections 7 0 and 8 0 Walk Testing and Final Tests To ensure co...

Reviews: