5.0 Configuration Switch Settings

The DS794Z has several features that are controlled using the
configuration switches.

CONFIGURATION

SWITCHES

ON

OFF

1 ON   

=  LED ON

1 OFF

 =  LED OFF

2 ON

 

and 3 ON 

=  Standard Sensitivity

2 OFF and 3 ON

 =  Intermediate Sensitivity

2 ON and 3 OFF

   =  High Sensitivity

4 ON and 5 OFF

   =  4 Day Motion Monitor

4 OFF and 5 ON

   =  30 Day Motion Monitor

4 OFF and 5 OFF

 =  Motion Monitor Off

1

2

3

5

4

5.1 LED Operation (S1)

ON

:

Allows the Alarm/Test LED to operate when activated by
motion.

OFF

:

The LED will not operate on alarm activation, but will  indicate
a supervision trouble condition.

5.2 Sensitivity Mode (S2 and S3)

Sensitivity modes depend on the type of coverage desired and the
installation environment.

Standard Sensitivity

:  The recommended setting for the DS794Z

with the 80 ft. (24.4 m) Mirror installed. Tolerates environment
extremes on this setting. 

Not recommended for the 120 ft. (36.6 m)

and 200 ft. (61 m) coverages.

Intermediate Sensitivity

: The recommended setting for the 120 ft.

and 200 ft. (36.6 m and 61 m) coverages or for locations where an
intruder is expected to cover only a small portion of the protected
area. Tolerates normal environments on this setting.

High Sensitivity

:  The setting for fast response to intruder signals.

For use in quiet environments where thermal and illumination
transients are not anticipated.

If both switches are in the Off position, the unit will default to the
Intermediate setting.

NOTE:

    Although the sensitivity modes provide different degrees of

tolerance to environmentally caused alarms, the installer
should assure peak background noise voltage readings do
not exceed ±0.15 VDC. (See Section 8.0 Final Tests).

5.3 Motion Monitor (S4 and S5)

Set switches S4 and S5 for the desired Motion Monitor time (see
Supervision Features). 

The detector is shipped with the Motion

Monitor feature Off.

6.0 Supervision Features

The DS794Z performs several supervision features that, combined
with the advanced motion detection capabilities of the detector,
provide an extremely high level of security. A supervision trouble
condition is indicated at the detector by the Alarm/Test LED (see the
Supervision Display Chart).

• The LED indicates the cause of the supervision trouble once per

second using coded pulses. The supervision trouble signal activates
the Trouble Output available on terminal 8.

The supervision features function as follows:

PIR:

  The operation of the PIR is electronically checked approximately

every 12 hours. If the PIR fails, the Alarm/Test LED will flash 4 times
and the Trouble Output will activate.

Motion Monitor Supervision:

  This feature verifies that the detector

has a clear view of the detection area. When selected using switches
S4 and S5, a supervision timer is activated. A trouble condition will
be indicated if the detector has not alarmed at least once during the
selected time period (this feature can be disabled by placing both
switches in the Off position). The time period selected should be
long enough to allow adequate time for holiday weekends.

Refer to Section 5.0 (Configuration Switch Settings) for proper
switch settings.

If the time period selected has elapsed from the last alarm, the LED
will flash 2 times and the Trouble Output will activate.

It is recommended that the 30 day timer be selected. This verifies
that the unit is operational and avoids nuisance trouble conditions
caused by holidays, vacations, etc.

LED

ON

Flashing 2
Flashing 4

CAUSE

Unit Alarm

Motion Monitor Timeout

PIR Self-test Failure

Supervision Display Chart

7.0 Setup and Walk Testing

If a different optical module is to be used:

• Slide the current module free from its housing. Install the new optical

module onto the housing. Make sure it snaps into place.

NOTE

:   Excessive handling of the front mirrored surfaces may lead

to performance degradation.

• Replace the front cover.

NOTE

:   All testing must be performed with the front cover in place.

• Apply power to the unit.

• Wait at least two minutes, after applying power, to start walk tests.

For best  results, wait at least 1 minute between walk tests to allow
the processing to adjust to the background.

NOTE

:   Walk testing should be done across the coverage pattern as

shown.

• The edge of the coverage pattern is determined when the Alarm/Test

LED indicator (and optional Sonalert, if installed) first turns on.

NOTE

:  The use of a Sonalert type device (sounder) will provide an

audible tone during the time the unit is in alarm. Of the  three
available connector pins, the center pin is positive (+) with
respect to either outside pin (outside pins are common (-)).

Walk test the unit from all directions to determine the boundaries.

• After completion of the walk tests, remove the Sonalert

  

(if installed).

Summary of Contents for DS794Z

Page 1: ...ct to DC power sources capable of supplying standby power if primary power fails Eighteen mA H required for each hour of standby time needed Four hours 72 mA H minimum are required for UL Listed Requirements Sensitivity Field selectable for Standard Intermediate or High Alarm Relay Silent operating Form C relay Contacts rated 125 mA 28 VDC maximum for DC resistive loads Do not use with capacitive ...

Page 2: ...sher and hex nut see drawing Hand tighten the hex nut Thread the bracket wiring through the stud and along the wiring channel in the detector s base to the area of the circuit board s terminal strip Return the circuit board to its base Slide the back of the circuit board under the tabs at the back of the base then snap the front into place Aim the detector in the desired general direction and tigh...

Page 3: ...rvision trouble once per secondusingcodedpulses Thesupervisiontroublesignalactivates the Trouble Output available on terminal 8 The supervision features function as follows PIR TheoperationofthePIRiselectronicallycheckedapproximately every 12 hours If the PIR fails the Alarm Test LED will flash 4 times and the Trouble Output will activate Motion Monitor Supervision This feature verifies that the d...

Page 4: ...ndicator is not desired after setup and walk tests are completed place configuration switch S1 in the Off position 9 2 Sealing the Wire Entrance The foam plug that is provided with the unit is for sealing the wire entrance from drafts and insects 9 3 Maintenance At least once a year the range and coverage should be checked according to Sections 7 0 and 8 0 Walk Testing and Final Tests To ensure co...

Reviews: