6.1.2
Perimeter Instant Arming
Use perimeter instant arming to arm only the exterior (perimeter) zones when you remain in the building. An exit
delay is in effect, but no entry delay is in effect so an alarm
does
occur upon entry.
The green Status LED must be lit and, if using a text keypad, “Ready to Arm” must be displayed. If the green
LED is not on or the keypad displays “Not Ready,” you must use other methods to arm the system (refer to Section
6.2.2 Force Arming on page 13 or Section 6.2.3 Zone Bypass on page 14).
Table 4: Perimeter Instant Arming
Equipment
Command Sequence
What Happens
What To Do
Text Keypad LED
Keypad
[PIN][No Entry]
[Perimeter Only]
• The red Armed LED flashes.
• “Perimeter Inst.” is displayed. *
• “Exit Now” is displayed during exit-delay. *
• The green Status LED lights steady.
• A single beep sounds.
• The red Armed LED lights steady when
the exit-delay period ends.
• The yellow Perimeter LED lights steady. **
• Only exterior protection zones are armed.
• Move freely around the
interior.
• Opening any exterior
door or window triggers
an alarm.
RF3341 Keypad
[PIN][#][2]
• The LED flashes indicating a signal was
sent to your security system.
• Only exterior protection zones are armed.
• Move freely around the
interior.
• Opening any exterior
door or window triggers
an alarm.
RF3332/RF3332E,
RF3334/RF3334E
Not applicable
* Text Keypad only
** LED Keypad only
Summary of Contents for DS7400XiV4-EXP
Page 1: ...EN User Guide Security System DS7400XiV4 EXP ...
Page 38: ...DS7400XiV4 EXP User Guide Notes EN 38 Bosch Security Systems 6 05 4998154961B Notes ...
Page 39: ...DS7400XiV4 EXP User Guide Notes EN 39 Bosch Security Systems 6 05 4998154961B Notes ...
Page 40: ... 2005 Bosch Security Systems 4998154961B Bosch Security Systems www boschsecuritysystems com ...