background image

Dinion Day/Night Camera

Safety | en

7

Bosch Security Systems

Installation and Operation manual

F.01U.163.823 | v1.0 | 2010.01

1.3

Important notices

Disposal -

 Your Bosch product was developed and 

manufactured with high-quality material and components that 
can be recycled and reused. This symbol means that 
electronic and electrical appliances, which have reached the 
end of their working life, must be collected and disposed of 
separately from household waste material. Separate collecting 
systems are usually in place for disused electronic and 
electrical products. Please dispose of these units at an 
environmentally compatible recycling facility, per 

European 

Directive 2002/96/EC

WARNING! 

Power disconnect for high voltage versions: A unit has power 
supplied whenever the power cord is inserted into the power 
source. The power cord plug is the main power disconnect for 
the unit. For pluggable equipment, install the socket outlet near 
the equipment so it is easily accessible.

WARNING! 

All-pole power switch: Incorporate an all-pole power switch, 
with a contact separation of at least 3 mm in each pole, into the 
electrical installation of the building.

CAUTION! 

Fuse rating: The branch circuit protection must be secured with 
a maximum fuse rating of 16 A. This must be in accordance with 

NEC800 (CEC Section 60)

.

CAUTION! 

The Low Voltage power supply unit must comply with EN/UL 
60950. The power supply must be a SELV-LPS unit or a SELV - 
Class 2 unit (Safety Extra Low Voltage - Limited Power Source). 

Summary of Contents for Dinion LTC0465

Page 1: ...Dinion Day Night Camera LTC0465 en Installation and Operation manual ...

Page 2: ......

Page 3: ...res 12 2 2 Unpacking 12 3 Connections 13 3 1 Power connection 13 3 1 1 Low voltage cameras 13 3 1 2 High voltage cameras 14 3 2 Video connection 14 3 2 1 Output Video signal 14 3 3 Alarm and relay connector 15 3 4 Lens mounting 16 3 5 Back focus adjustment 17 3 6 Mounting the camera 19 3 7 Day Night switching 19 4 Configuration 20 4 1 Menus 20 4 1 1 Top level menus 20 4 1 2 Menu navigation 20 4 2 ...

Page 4: ...10 01 Installation and Operation manual Bosch Security Systems 4 3 4 VMD submenu remotely via Bilinx only 25 4 4 Install menu structure 27 4 4 1 Lens Wizard submenu 27 4 4 2 Alarm submenu 29 4 4 3 Defaults submenu 30 5 Technical Data 31 5 1 Specifications 31 Glossary 33 ...

Page 5: ... will result in an electrical shock serious bodily injury or death WARNING Medium risk Indicates a potentially hazardous situation If not avoided this could result in minor or moderate bodily injury CAUTION Low risk Indicates a potentially hazardous situation If not avoided this could result in property damage or risk of damage to the unit NOTICE This symbol indicates information or a company poli...

Page 6: ... Take precautions to protect the unit from power and lightning surges 5 Controls adjustment Adjust only those controls specified in the operating instructions Improper adjustment of other controls may cause damage to the unit 6 Power sources Operate the unit only from the type of power source indicated on the label 7 Servicing Unless qualified do not attempt to service this unit yourself Refer all...

Page 7: ...y per European Directive 2002 96 EC WARNING Power disconnect for high voltage versions A unit has power supplied whenever the power cord is inserted into the power source The power cord plug is the main power disconnect for the unit For pluggable equipment install the socket outlet near the equipment so it is easily accessible WARNING All pole power switch Incorporate an all pole power switch with...

Page 8: ...ch can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and receiver connect the equipment into an outlet on a circuit different from that to which the receiver is connected consult the dealer or an experienced ...

Page 9: ... installation particulière Il est possible de déterminer la production d interférences en mettant l appareil successivement hors et sous tension tout en contrôlant la réception radio ou télévision L utilisateur peut parvenir à éliminer les interférences éventuelles en prenant une ou plusieurs des mesures suivantes Modifier l orientation ou l emplacement de l antenne réceptrice Éloigner l appareil ...

Page 10: ...rity or signaling aspects of this product UL MAKES NO REPRESENTATIONS WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT Disclaimer Underwriter Laboratories Inc UL has not tested the performance or reliability of the security or signaling aspects of this product UL has only tested fire shock and or casualt...

Page 11: ...accordingly Note This manual has been compiled with great care and the information it contains has been thoroughly verified The text was complete and correct at the time of printing The ongoing development of the products may mean that the content of the user guide can change without notice Bosch Security Systems accepts no liability for damage resulting directly or indirectly from faults incomple...

Page 12: ...nications Enhanced video motion detection Backlight compensation Lens autodetection Lens wizard for easy backfocus Alarm input and relay output 2 2 Unpacking Unpack carefully and handle the equipment with care The packaging contains Dinion Day Night camera CCD protection cap mounted on camera Spare lens connector male These instructions If equipment has been damaged during shipment repack it in th...

Page 13: ...er from a 24 VAC or 12 VDC class 2 power supply as follows Use AWG16 to 22 stranded wire or AWG16 to 26 solid wire cut back 5 mm 0 2 in of insulation Push in the tabs and insert the wires Note These connections are not polarity sensitive CAUTION Before proceeding disconnect the power from the power supply cable Ensure that the voltage of the unit matches the voltage and type of the power supply be...

Page 14: ...re 3 2 High voltage power connection Connect the power cable of a high voltage camera to either a 230 VAC or a 120 VAC power supply outlet depending on the version 3 2 Video connection Figure 3 3 BNC connectors 3 2 1 Output Video signal The camera has a BNC connector to connect the video coax cable with a male BNC connector VIDEO ALARM VIDEO ALARM Video BNC ...

Page 15: ... in of insulation Default relay position normally open n o no alarm Alarm output relay switching capability Max voltage 30VAC or 40 VDC Max 0 5 A continuous 10 VA Alarm in TTL logic 5V nominal 40 VDC max DC coupled with 22 kOhm pull up to 3 3 V Alarm in configurable as active low or active high Max 42 V allowed between camera ground and each of the relay pins Pin Alarm socket 1 Alarm in ground 2 A...

Page 16: ...it is detected on the lens connector the on screen display OSD failure message LENS SHORT CIRCUIT is shown The lens circuit is automatically disabled to avoid internal damage Remove the lens connector and check the pin connections CAUTION To avoid damaging the CCD sensor when using a C mount lens make sure a lens adapter ring not included is mounted onto the camera before mounting the lens Lenses ...

Page 17: ...g for example at night When back focusing varifocal lenses adjust to obtain a sharp picture in both wide angle and tele positions for both far and near focus When back focusing zoom lenses ensure the object of interest remains in focus throughout the entire zoom range of the lens To adjust back focus 1 Open the slide door panel at the side of the camera 1 Unlock the back focus locking button 2 Pre...

Page 18: ...ation and Operation manual Bosch Security Systems 5 Lock the back focus locking button 6 Press and hold the center key for more than 1 second until all the menus disappear 7 Close the side door panel Note To backfucus a zoom lens see the zoom lens installation guide Bosch Bosch ...

Page 19: ...n settings If Auto switching mode is selected the camera automatically switches the filter depending on the observed light level The switching level is programmable In Auto switching mode the camera prioritizes motion the camera gives sharp images without motion blur as long as the light level permits or color the camera gives color pictures as long as the light level permits The camera recognizes...

Page 20: ...l menus a Main menu and an Install menu The menus have functions that can be selected directly or submenus for more detailed set up To access the Main menu press the menu select button center for less than 1 second The Main menu appears on the monitor Select and set up the picture enhancement functions If not satisfied with your changes recall the default values The camera also has an Install menu...

Page 21: ...Bilinx This camera is equipped with a coaxial communications transceiver also referred to as Bilinx In combination with VP CFGSFT the camera setting can be changed from any point along the coaxial cable All menus can be accessed remotely giving full control of the camera With this method of communication it is also possible to disable the local keys on the camera To avoid loss of communication on ...

Page 22: ...ns a negative value is more useful for very bright conditions Shut AGC Submenu Picture enhancement and performance Day Night Submenu Control day night switching BLC On Off Set to On to enable Back Light Compensation BLC Color Submenu White balance and color rendition Sync Internal Line lock Internal for free running camera operation Line lock to lock to the AC power supply Vphase 0 2 358 Adjusts t...

Page 23: ...utter speed FL flickerless mode avoids interference from light sources recommended for video iris or DC iris lenses only FIXED forces a fixed shutter speed Gain On Off On the camera automatically sets the gain to the lowest possible value needed to maintain a good picture Off sets AGC off Autoblack On Off Autoblack On automatically increases the visibility of details even when scene contrast is le...

Page 24: ... scene illumination level Monochrome the IR cut off filter is removed giving full IR sensitivity Color the camera always produces a color signal regardless of light levels Switch level 15 to 15 Sets the video level in Auto mode at which the camera switches to monochrome operation A low negative value means that the camera switches to monochrome at a lower light level A high positive value means th...

Page 25: ...es the color settings Red gain 5 to 5 Adjusts the Red gain to optimize the white point Blue gain 5 to 5 Adjusts the B gain to optimize the white point EXIT Returns to main menu Item Selection Description VMD Off Silent OSD Off Video Motion Detection VMD is off Silent video motion generates silent alarm OSD video motion generates on screen text message alarm VMD area Submenu Select to enter the are...

Page 26: ... now be moved Pressing Select again freezes the area and exits the area menu There is one programmable VMD area Note When VMD is enabled normal light fluctuations or environmental factors can contribute to false positive alarms Because of this it is recommended to not connect the VMD triggered alarm output of the camera to a monitored alarm system as the false positive alarms may be considered a n...

Page 27: ...nu Select to optimize the camera lens combination backfocus point Comm On Off Communications enabled or disabled If Off Bilinx communication is disabled Alarm Submenu Program the alarm input and output functionality Defaults Submenu Returns all settings for all modes to factory defaults Item Selection Description Detected lens Shows the type of lens detected when auto lens detection is used Set Ba...

Page 28: ...tment as required 4 Lock the back focus locking button 5 Adjust lens opening to suit scene Adjustment procedure Video iris Lens 1 Unlock the back focus locking button 2 Access the Lens Wizard menu 3 Set Back Focus Now is highlighted in the menu 4 Turn the back focus adjustment as required 5 Lock the back focus locking button 6 Select Set LVL in the menu the Level bar appears 7 Point the camera at ...

Page 29: ...ts the action of the camera when the alarm input is active Alarm out Action VMD Remote Day Night Filter move VMD output relay activates on VMD alarms Remote make the output relay available to remote communication devices Day Night output relay activates when camera is in monochrome mode Filter move output relay activates just before the IR filter starts moving and de activates when video level has...

Page 30: ...on manual Bosch Security Systems 4 4 3 Defaults submenu Item Selection Description Restore All No Yes Restores all settings to their default factory values Select YES then press the Menu Select button to restore all values When completed the message RESTORED is shown EXIT Returns to Install menu ...

Page 31: ...mination 0 3 lux 0 012 lux in monochrome mode Imager 1 3 inch Interline CCD Resolution 540 TVL SNR 50 dB Video output 1 Vpp 75 Ohm Synchroniza tion Internal Line Lock selectable Shutter AES 1 60 1 50 to 1 150000 automatic flickerless fixed selectable Day Night Color Mono Auto AGC AGC On 20 dB or Off 0 dB selectable Back Light Compensation BLC One area center weighted White Balance ATW AWBhold 2500...

Page 32: ...nual Bosch Security Systems Power consumption 4 W Dimensions H x W L 58 x 66 x 122 mm 2 28 x 2 60 x 4 80 in without lens Weight 450 g 0 99 lb without lens Tripod mount Two 1 4 20 UNC isolated bottom and non isolated top Operating temperature 20 C to 55 C 4 F to 131 F Controls OSD with softkey operation ...

Page 33: ...A feature that allows a color camera to automatically adjust its output color to give a natural color independent of the lighting used AutoBlack A technique of boosting the video signal level to produce a full amplitude video signal even when the scene contrast is less than full range glare fog mist etc AutoIris The lens iris opening is automatically adjusted to allow the correct illumination of t...

Page 34: ... CCD Format Indicates the size of the camera sensor used In general the larger the sensor the more sensitive the camera and the better the image quality The format is quoted in inches for example 1 3 or 1 2 inch Charged Coupled Device CCD A CCD is a type of solid state image sensor used in CCTV cameras The sensor converts light energy into electrical signals Color Temperature A measure of the rela...

Page 35: ...int that appears in focus The smaller the aperture the greater the depth of field Dynamic Noise Reduction DNR A digital video processing technique that measures the noise image artifacts in the picture and automatically reduces it E Electronic iris Electronic iris or AES Automatic Electronic Shutter adjusts the camera shutter speed to compensate for lighting changes In some cases this can eliminat...

Page 36: ...lamps with the appropriate filters LEDs or lasers CCD sensors are less sensitive to IR than visible light but IR can significantly increase the total illumination level leading to a much better image at low light levels IRE Institute of Radio Engineers A measurement of video amplitude that divides the area from the bottom of sync to peak white level into 140 equal units 140 IRE equals 1V peak to p...

Page 37: ... measure of the fine detail that can be seen in an image For analog systems this is typically measured in horizontal Television Lines or TVL The higher the TVL rating the higher the resolution S Saturation The amplitude of the chrominance signal affecting the vividness of the color Sensitivity A measure of the amount of light required to provide a standard video signal Sensitivity values are state...

Page 38: ...rom the other twisted pairs in the cable UTP is the primary wire type for telephone usage and the most commonly used type of networking cable V VMD Video Motion Detection An algorithm for motion detection in which the camera compares the current image with a reference image and counts the number of pixels that have changed between the two images An alarm is generated when the number of pixel chang...

Page 39: ......

Page 40: ...Bosch Security Systems www BoschSecurity com Bosch Security Systems 2010 ...