Assigning an IP Address
Before you can operate a camera in your network you must first
assign it an IP address that is valid for your network.
The following default address is preset at the factory:
192.168.0.1
1.
Start a terminal program such as HyperTerminal.
2.
Enter the user name service. The terminal program displays
the main menu.
3.
Enter command 1 to open the IP menu.
4.
Enter 1 again. The terminal program displays the current IP
address and prompts you to enter a new IP address.
5.
Enter the desired IP address and press Enter. The terminal
program displays the new IP address.
6.
Use the displayed commands for any additional settings you
require.
Note:
You must reboot to activate the new IP address, a new subnet
mask, or a gateway IP address.
Reboot
Briefly interrupt the power supply to the camera for a reboot
(disconnect the power supply and switch on again after a few
seconds).
Additional Parameters
Use the terminal program to check other basic parameters and
modify them where necessary. Use the on-screen commands in
the various submenus to do this.
36
en | Troubleshooting
DINION IP ultra 8000 MP
2015.04 | v2.0 | AM18-Q0688