Troubleshooting
LED error status
The camera has four LEDs on the rear panel:
–
Two LEDs indicate the camera status (red for error; green
for OK)
–
Two LEDs (green and orange) beside the network
connection indicate the LAN and PoE status
Resolving problems
The following table is intended to help identify the causes of
malfunctions and correct them where possible.
Malfunction
Possible causes
Solution
No image
transmission to
remote location.
Defective camera.
Connect a local
monitor to the
camera and check
the camera function.
Faulty cable
connections.
Check all cables,
plugs, contacts and
connections.
Incorrect encoder
stream property set
for connection to
hardware decoder.
Select the H.264 MP
SD option on the
Encoder Streams
configuration page.
No connection
established, no
image
transmission.
Incorrect unit
configuration.
Check all
configuration
parameters (reset to
factory default if
necessary).
8
8.1
8.2
30
en | Troubleshooting
DINION IP ultra 8000 MP
2015.04 | v2.0 | AM18-Q0688
Bosch Security Systems
Summary of Contents for DINION IP ultra 8000 MP
Page 1: ...DINION IP ultra 8000 MP NBN 80122 en Installation Manual ...