Malfunction
Possible causes
Solution
No connection
established, no
image
transmission.
Incorrect unit
configuration.
Check all
configuration
parameters (reset to
factory default if
necessary).
Faulty installation.
Check all cables,
plugs, contacts and
connections.
Wrong IP address.
Check the IP
addresses (terminal
program).
Faulty data
transmission within
the LAN.
Check the data
transmission with
ping.
The maximum
number of
connections has
been reached.
Wait until there is a
free connection and
call the transmitter
again.
No audio
transmission to
remote station.
Hardware fault.
Check that all
connected audio
units are operating
correctly.
Faulty cable
connections.
Check all cables,
plugs, contacts and
connections.
Incorrect
configuration.
Check audio
parameters on the
Audio configuration
and LIVE page
functions pages.