Starting up
Before starting
Install the software required DDU 8 operation. It is developed for Windows
2000/XP/Vista/7.
Following software versions are used in this manual:
▪ DDU 8 setup, configuration and calibration: RaceCon later than 2.5.0.400.
Set up the 100 Mbit Ethernet connection to the DDU 8.
▪ The Ethernet port has ‘cable auto crossover’ functionality
Minimum wiring loom of the Life connector (red):
Pin
Description
Pin 1+2+3
12 V supply voltage
Pin 4+5
GND supply voltage
Pin 6
Ethernet Tx+
Pin 7
Ethernet Tx‐
Pin 8
Ethernet Rx+
Pin 9
Ethernet Rx‐
Pin 10
Ethernet Screen
Setting up the network interface
The DDU 8 contains a DHCP server, network addresses can be assigned automat‐
ically to the configuration PC. The IP address of DDU 8 is 10.10.0.208.
1. Switch off the PC’s firewall.
2. Set up the PC’s network interface as shown in the screenshots.
Select
'Internet Protocol
(TCP/IP)'
Click
'Properties'
Select 'Obtain
an IP adress
automatically'
Click 'OK'
when done
Starting the unit
The DDU 8 powers up by turning on the ignition of the car. At startup the DDU 8
will display a Bosch logo.