DCN Next Generation Release Notes
en | 11
Bosch Security Systems| 2014-10-31
Product/function
Problem
Solution
DCN-SWWA
Does not work with
DCN-SW
DCN-SWWA 1.1.1 requires DCN-SW 4.2x or later
DCN-SWWA 1.0.1 requires DCN-SW 4.1x
DCN-SWWA
Webcast will stop
after 12 hours.
Maximum webcast length of a webcast is 12 hours. It
will stop automatically.
DCN-SWWA
No audio on SDI input
box
With setup, please note if there is no audio, resetting
the Audio to SDI box most of the time will solve the
problem.
DCN-SWWA
Opinion Poll and
Multiple Choice
information from
DCN-SWSMD is not
supported.
none
DCN-SWWAEC
Slave languages not
added after using
Refresh function.
Refresh webcast will only effect PowerPoint slides.
Load webcast will add the languages
DCN-SWWAEC
Webcast will not start
on slave PC’s.
Close the publisher on slave PC’s before starting a
new webcast.
Not all text is
shown on
Webcasting player
For security reasons,
all text between the
signs ‘<’and ‘>’ is
removed and currently
not shown on the
webcasting player
website.
Do not use the “<” and “>” characters in DCN-SW
(e.g. meeting information, session information, voting
information, delegate names) or Webcast Planner
Website.
Wireless system in
combination with
Integrus
No audio on DCN
wireless units when
powering up DCN-
CCU2 and Integrus
transmitter
simultaneous.
First power up the DCN-CCU2. After it is powered up,
power up the Integrus transmitter.
Not able to
download DCN-
CCU2 firmware
DCN-DLT is not able
to download the
firmware of the CCU
Check if the DCN-SW server is not running:
1.
Exit the DCN-DLT program
2.
Check if the DCN-CCU2 does not report PC
on it’s display. If it does Stop the DCN-SW
server via Start\ <Search programs and files>
SERVICES. Services (local). And check if PC
disappears.
3.
Start DCN-DLT (PC will now re-appear in the
CCU2 screen, but that is correct) and start
the download.
If the download still fails, do the following:
1.
Power off and open the DCN-CCU2
2.
Set switch 8 of S600 to ON and power on the
CCU.
3.
Download the CCU using the DCN-DLT.
4.
After a succesfull download, power off the
CCU, set switch 8 of S600 to OFF again and
power on the CCU.
HD Conference
Dome
The HD Conference
Dome will show an
incorrect name &
picture combination if
a new pre-position is
asked before it
reaches it’s pre-
position.
Do not activate another microphone until the HD
Conference Dome has reached it’s pre-position.
DCN-UPTK
The type of the unit
connected to the
UPTK is not valid.
This notification can occur when the DCN-UPTK unit
is used extensively. Please replace the connection
cable.