DCN Next Generation Release Notes
en | 10
Bosch Security Systems| 2014-10-31
Product/function
Problem
Solution
DCN-SW
On 64-bit operating
systems, it might
difficult to find
previous SQL-server
during DCN-SW
installation, when
initial SQL-installation
was not default.
During installation of DCN-SW the installation process
might not be able to find the previous SQL-server, in
case during initial installation another name for the
SQL-server was created, instead of using the default
name. Therefore it is recommended to use the default
name and folder during initial SQL-installation. If a
SQL-server with a non-default name needs to be
found, the correct name should be entered manually
in the applicable box during DCN-SW installation.
DCN-SW
System overview
does not show all
connected devices
when system is still
powering up.
Wait until DCN-system is powered up completely and
then check the connected devices via DCN-SW
configuration application VIEW \ System Overview.
DCN-SW
DCN-SW Master
Volume is different
from CCU volume
control
When the Master Volume of the CCU has been
changed while DCN-SW was disconnected, the DCN-
SW Master Volume will not reflect the CCU-setting.
Changing the DCN-SW volume setting, will make
them identical again.
DCN-SW
Downgrade to
versions <3.10 not
possible.
Manually uninstall SWL server 2008.
Note that the DCN-SW database (the database
contains all settings like seats, meetings, synoptic
layouts, etc.) will always be removed during a
downgrade.
DCN-SW
Unexpected
behaviour or no
reaction of DCN-SW.
Due to Windows Automatic Updates some critical
components like SQL Server Express might be
temporarily not available for DCN-SW.
Do not set Automatic Updates to Automatic or restart
your system after the Automatic updates have been
installed.
DCN-SW
Generates errors after
Windows Stand by..
Disable Stand by functionality in the Windows
operating system.
DCN-SWPV
Secret mode does not
work in ad-hoc voting
Update to version 2.80 or higher
DCN-SWPV
Voting attention tone
cannot be changed
during a running
meeting.
The voting attention tone can be changed in the
voting template but becomes effective after a vote has
been selected or started.
DCN-SW setup
repair
Error code 2869 or
Fatal error during
installation.
Remove DCN-SW with DCN-SW setup and make a
new installation. Settings are stored in the SQL-
database and can be re-used in the new installation.
DCN-SWSMV
Error notification upon
closing DCN-SWSMV
directly after opening
it.
Please wait at least 10 seconds to close DCN-
SWSMV after opening it.
DCN-SWSMV help
file
When opening help
file you get an error.
Just close the error notification.
DCN-SWSMV
DCN-SWSMV will not
start
Voting legends cannot be changed into “Not Voted”.
Remove “BCPCSettings.xml” which can be found:
For XP:
“…\Documents and Settings\All Users\Application
Data\Bosch\DCN Synoptic Microphone and Voting
Software\x.xx”
For Vista:
“…\Programdata\Bosch\DCN Synoptic Microphone
and Voting Software\x.xx”