(See Fig. 1.)
(a) Switch on the electrical mains supply to the boiler.
(b) Ensure that any external controls connected to the boiler, such

as a room thermostat, are on a high setting.

(c) If a programmer is fitted set it to the correct time of day and

position the selectors to ON.

(d) Ensure the switch on the Outdoor control box is in the ‘run’

position.

(e) Turn the thermostat control knob to the desired position

(see Fig. 2: temperature control).

(f) Your boiler will now commence a start sequence, in which a

pre-ignition period   of approximately 15 seconds is followed
by a supply of atomised oil being introduced into the
combustion chamber.  Ignition then occurs, followed by a post-
ignition period of approximately 20 seconds.

(g) Your boiler is now in a steady run condition and will remain so

until the water temperature reaches the temperature set on the
control thermostat.  At this point the burner will stop and the
boiler will shut down.  The sequence will continue until the
boiler is programmed - either manually or by an automatic
programmer - for a period of shutdown.

Fig. 1. Control Facia

HOW TO START YOUR

BOILER

Overheat
Thermostat
Reset Button

Switch

TEMP

Isolate
mains
supply
before
removing
Burner
or any
electrical
cover.

Bosch Thermotechnik

Temperature
Control Knob

Serial Number
Label

Side view of
switch in
‘RUN MODE’

RUN

SERVICE

Frost Thermostat

Outdoor Control Box

Summary of Contents for Danesmoor 12-14

Page 1: ...SCH 50 70 70 90 90 110 FLOOR STANDING OIL FIRED PRESSURE JET BOILERS WHEN FITTED INSIDE THE OUTDOOR PACK USER INSTRUCTIONS CUSTOMER CARE GUIDE IMPORTANT Please discard previous User Instructions and retain only the Worcester Outdoor Pack user instructions ...

Page 2: ...ester boiler offers you the very best of everything quality efficiency economical running costs proven reliability and value for money What s more you also have the assurance of our no nonsense 2 year parts and labour guarantee And it s backed up by Worcester Care Call a complete maintenance scheme to keep your boiler operating at peak condition and efficiency No wonder that more and more people a...

Page 3: ...TILATION AND AIR SUPPLY Air for the boiler is supplied via the flue terminal and no other air supply is required ROUTINE MAINTENANCE It is essential that your boiler is installed and serviced by a competent heating engineer and Worcester Heat Systems will be pleased to arrange regular servicing and a comprehensive maintenance contract Servicing should be carried out at least once a year for boiler...

Page 4: ...ter Bosch oil fired pressure jet boiler when fitted inside Outdoor Pack provides both domestic hot water and full central heating with outputs ranging from 51 000 to 109 000 Btu h Domestic hot water must be supplied via a conventional indirect hot water system utilising an indirect double feed cylinder WARNING NOTE Completely isolate the appliance from inside the property before accessing your boi...

Page 5: ...l being introduced into the combustion chamber Ignition then occurs followed by a post ignition period of approximately 20 seconds g Your boiler is now in a steady run condition and will remain so until the water temperature reaches the temperature set on the control thermostat At this point the burner will stop and the boiler will shut down The sequence will continue until the boiler is programme...

Page 6: ...within the indicated range as shown in Fig 2 Higher settings obviously mean hotter radiators and rooms will reach the required temperature quicker The ideal setting varies from property to property and can only be established by trial and error and experience a setting of medium to high should serve as a good initial guide PLEASE NOTE The control knob must not be set below the first indicating bar...

Page 7: ... a signal lamp located on the burner control box To reset the burner lockout condition remove the Outdoor Pack front cover and boiler front cover See section Accessing your boiler controls and allow two minutes before pressing the illuminated lockout reset button which is mounted on the burner control box Provided the system is still calling for heat the burner will then operate and commence anoth...

Page 8: ... found and the appliance has been installed within the past 24 months provided that the first annual service has been carried out on a boiler which is more than 12 months old Reasonable evidence of this must be supplied on request call out charge will be made where The appliance has been installed for over 24 months The appliance has been installed for more than 1 year but less than 2 years and ha...

Page 9: ...if necessary See programmer operating instructions If the boiler is programmed for central heating check the room thermostat is turned on Check any other control devices fitted Check the switch on the Outdoor Pack is set in the Run mode Turn the temperature control knob to maximum If the boiler is hot allow time to self reset Press the reset button See section High limit thermostat Check power sup...

Page 10: ...er however if you have difficulty making a satisfactory arrangement simply contact Worcester Heat Systems on 0345 256206 for help If you would like to know more about Worcester s extended warranty options please tick the appropriate box on your Guarantee Registration card SERVICE CENTRES Contact Numbers UK Call Centre Tel 08457 256 206 UK Call Centre Fax 01905 757536 Scotland only Fax 01506 441 68...

Page 11: ...of of commissioning proof where appropriate of the first 12 month service and the address of the householder 4 That Worcester Heat Systems Limited will not accept responsibility for damage caused by faulty installation neglect misuse or accidental damage the non observance of the instructions contained in the Installation and Operating Instructions leaflets 5 That the appliance has been used only ...

Page 12: ...Worcester Heat Systems Limited Cotswold Way Warndon Worcester WR4 9SW Telephone 01905 754624 Fax 01905 754619 Technical Service Helpline 08705 266241 www worcester bosch co uk 8 716 102 841a 06 01 ...

Reviews: