5.0 Batteries 

This device is intended for use with AC 
power. Extended use of batteries is not 
recommended due to the power 
requirements of the unit. 

This unit includes a feature that monitors the charge 
of the batteries. If the battery voltage falls below 16 V, 
the unit displays 

Lob

. If the battery voltage falls below 

15 V, the unit displays 

bAd

. The display of 

Lob

 or 

bAd

 indicates insufficient power for programming. 

D8125MUX communications might still function 
properly even if these conditions exist. 

To preserve the life of the batteries, 
remove them from the multiplex point 
programmer whenever you will not use the 
unit for any length of time. 

6.0 Specifications 

Table 3: Specifications 

Description Value 

Display 

Three-digit, seven-segment LED 

Power 

16.5 VAC (20 VA to 50 VA) external 
power source (recommended), or two 
9 VDC batteries (optional) 

This product is intended for use with AC 
power. Extended use of batteries is not 
recommended due to the power 
requirements of the unit. 

Summary of Contents for D5060

Page 1: ...ded power cable to the output terminals of a 16 5 VAC transformer Insert the plug end into the jack labeled EXT POWER on the programmer Refer to Figure 2 Figure 3 and Figure 4 2 For control panels use the serial cable provided to connect the D8125MUX to the D9412G D9412 D9112 D7412G D7412 D7212G or D7212 Control Panel to the jack labeled SERIAL PORT on the programmer 3 For MUX devices without DIP ...

Page 2: ...ints 1 The D5060 displays the prompt Adr after it is powered on This indicates that it is ready to begin programming 2 If the MUX device has no DIP switches connect the D5060 to the point to be programmed Figure 2 If the MUX device has DIP switches program the device using its DIP switches The point must be connected only to the programmer and not to the D8125MUX or the MUX bus If programming poin...

Page 3: ...installation information 4 1 Reading Information from the D8125MUX 1 To put the unit into Interrogation Mode press and hold 7 and 9 simultaneously until the unit beeps The LED marked INTERROGATION MODE lights 2 The display shows A dr and the left most decimal point lights prompting the user to enter a starting address Enter an address followed by 3 The Interrogation LED flashes Press to read point...

Page 4: ... the unit displays bAd The display of Lob or bAd indicates insufficient power for programming D8125MUX communications might still function properly even if these conditions exist To preserve the life of the batteries remove them from the multiplex point programmer whenever you will not use the unit for any length of time 6 0 Specifications Table 3 Specifications Description Value Display Three dig...

Reviews: