20
en | Installation Manual
CRS-SWM-TA869 | CRS-WM-TA869 | ISA-WM-869
F.01U.045.268 | V4 | 2014.12
Installation Manual
Bosch Security Systems
Technical
Specifications
Triggers
Environmental conditions
Housing
Power supply requirements
Passive infrared
detector
Movement in moni-
toring zone.
Housing and
wall tamper
contact
(depending on
installation)
Transmits an alarm
message if the top
of the housing is
removed from the
base or if the detec-
tor is torn off the
wall.
Environment
Indoors, dry
EN50131-1
Environmental
class II
Relative
humidity
Up to 95%,
non-condensing
Operating
temperature
-10 °C to +55 °C
Storage
temperature
-20 °C to +80 °C
Color
Cream white
Dimensions
(H x W x D)
12.2 x 6.2 x 5.2 cm
Battery
durability
From 18 months to
4 years, depending
on the area of instal-
lation and number
of transmissions.
Battery
requirements
Four 1.5 V alkaline
cells (AA)
Recommended
batteries
- Duracell® MN1500
or PC1500
- Eveready® E91
- Panasonic®
AM-3PIX/B
Supply voltage
2.3 VDC to 3.0 VDC
Automatic
test signal
Every 24 hours at
least
Message:
"Battery Low"
On activation or
automatic test
signal. Following
a "Battery Low"
message, the bat-
tery should be
changed within one
week.