28
en | Operation
NurseCall N46 Wall Transmitter
970.030 | v1.1 | 2009.09
User Manual
Bosch Security Systems
State before action: Assistance with staff presence
State before action: Assistance without staff presence
State before action: Staff presence without alarm
Action
State
Relay contact
Signal lamp
Radio Message
Assistance with staff
presence
(none)
Coded key insertion
Assistance with staff
presence
(unchanged)
Staff arrival with
code
Coded key removal
Assistance without
staff presence
Staff departure with
code
Action
State
Relay contact
Signal lamp
Radio Message
Assistance without
staff presence
(none)
Coded key insertion
Alarm with staff
presence
Staff arrival with
code
Coded key removal
(not possible)
Action
State
Relay contact
Signal lamp
Radio Message
Staff presence
without alarm
(none)
Coded key insertion
Staff presence
without alarm
(unchanged)
Staff arrival with
code
Coded key removal
Stand-by
Staff departure with
code