List of equipment
3.3.1 EPS
Pos.
Abbreviation
Designation
Function
801
Control valve
Test oil feed pressure
802
M2
Hydro-gear pump
Test oil supply
803
Y3
Control valve
Coolant control
804
Heat exchanger
Test oil cooling
805
Single-stage filter
806
Control valve
Lubricating oil supply
807
Hydro built-in filter
Lubricating oil
808
Hydro intake filter
Test oil
809
Shutoff valve
810
M3
Hydro gear pump
Lubricating oil supply pump
811
Pressure gage (0 - 600 kPa)
For supply pressure (low pressure)
812
Pressure gage (0 - 6 kPa)
For supply pressure (high pressure)
813
Pressure gage (-100 - 250 kPa)
For suction line and internal pump pressure measurement
814
Pressure gage (0 - 1,6 MPa)
Supply pump pressure
815
Pressure gage (0 - 1 MPa)
Lubricating oil supply pressure
816
B2
Limit switch
Float switch for test oil tank
835
Control valve
For pump overflow pressure
3.3.2 CRS 845
Pos.
Abbreviation
Designation
Function
830
Common rail
High-pressure rail for pressure generation
830.1
Pressure limiting valve
Safety shutoff valve
830.2 Y6, Y7, Y8
Pressure control valve
For pressure generation
830.3
Common rail
High-pressure rail
830.4 B10
Pressure sensor (180 MPa)
Safety monitoring (redundancy)
830.5 B9
Pressure sensor (250 MPa)
Pressure measurement in high-pressure rail
831
Distributor
Injection distributor
839
Throttle
For suction line (CP 2)
3.3.3 Safety monitoring
Pos.
Abbreviation
Designation
Function
B11-13
Inductive proximity switch
Switch for safety monitoring
X10
Junction box
Terminal box for B11-13 proximity switch
X10.1
Connector
Connection to control unit
X10.2
Connector
Connection to B13 sensor
3.3.4 Control unit
Pos.
Abbreviation
Designation
Function
A10
Control unit
Control for CP test
A10.1
Control PCB
Control for CP test
F1
Fusible cutout
Fuse for 24 V input voltage
F2
Fusible cutout
Fuse for 12 V input voltage
F3
Fusible cutout
Fuse for regulated 5V and 12V internal voltage supply
V19
Control LED
12 V supply display
V21
Control LED
24 V supply display
V22
Control LED
12 V or 24 V supply for PCV, DMV1 and ZME display
V23
Control LED
12 V or 24 V supply for EAV and DMV2 display
V24
Control LED
Microcontroller operation control
V26
Control LED
Regulated 12V supply display
V27
Control LED
Regulated 5V supply display
3.3.5 Cooler
Pos.
Abbreviation
Designation
Function
832
Cooler
Cooler for injection quantity
833
Throttle device
Feed control for cooler
Summary of Contents for CRS 845
Page 4: ... 2 Montage Demontage 2 1 Spritzschutzgehäuse 2 1 1 Spritzschutztüren 458797 1 4587979 3 ...
Page 5: ... 2 1 2 Gehäuse 2 2 Sicherheitsüberwachung 458797 2 458797 4 ...
Page 7: ... 2 4 Ansteuergerät 2 5 Überlaufregelventil 458797 8 458797 9 ...
Page 8: ... 2 6 Einstufenfilter für CP 2 Sonderzubehör 25 20 15 10 5 0 458797 29 ...
Page 30: ...30 2 1 2 Housing 2 2 Safety monitoring 458797 2 458797 4 ...
Page 32: ...32 458797 8 2 4 Control device 2 5 Overflow control valve 458797 9 ...
Page 33: ...33 2 6 SIngle stage filter for CP2 Special accessories 25 20 15 10 5 0 458797 29 ...