21.6 Installation in a tall unit
Observe the installation dimensions and the safety
clearances in a tall unit.
To ventilate the appliance, the intermediate floor must
have a ventilation cut-out.
If the tall unit has another back panel in addition to the
element back panels, this must be removed.
Do not fit the appliance too high up; it must be pos-
sible for accessories to be removed easily.
21.7 Combination with a warming drawer
First fit the warming drawer. Follow the installation in-
structions for the warming drawer.
Slide the appliance, on the warming drawer, into the fit-
ted cabinet. When sliding in the appliance, do not dam-
age the warming drawer's panel.
21.8 Corner installation
Observe the installation dimensions and the safety
clearances when installing in a corner.
To ensure that the appliance door can be opened, you
must take the minimum dimensions into consideration
when installing in a corner. The dimension is de-
pendent on the thickness of the unit front and the
handle.
21.9 Electrical connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
WARNING ‒ Danger: Magnetism!
The appliance contains permanent magnets. These
may affect electronic implants, e.g. heart pacemakers
or insulin pumps.
▶
Persons with electronic implants must stay at least
10 cm away from the appliance.
¡
The appliance corresponds to protection class I and
must only be operated with a protective earth con-
nection.
¡
The fuse protection must correspond to the power
rating specified on the appliance's rating plate and
to the local regulations.
¡
The appliance must be disconnected from the
power supply whenever installation work is being
carried out.
¡
If the power cable is damaged, it must be replaced
by the manufacturer, customer service or a person
with equivalent qualifications in order to eliminate
any risks.
¡
Contact protection must be guaranteed by the in-
stallation.
Connecting the appliance to the electricity
supply
Note:
The appliance must only be connected to a pro-
tective contact socket that has been correctly installed.
1.
Insert the non-heating appliance plug of the power
cable into the appliance.
Check that the non-heating appliance plug is inser-
ted properly.
2.
Insert the mains plug of the appliance into a nearby
socket.
Ensure that the mains plug of the mains power
cable is easily accessible after installation of the ap-
pliance. If free access to the mains plug of the
power cable is not possible, an all-pole isolating
switch must be installed in the permanent electrical
installation according to the installation regulations.
Electrically connecting an appliance without a
protective contact plug
Note:
Only a licensed professional may connect the ap-
pliance. Damage caused by incorrect connection is not
covered under the warranty.
An all-pole isolating switch must be integrated into the
permanent electrical installation according to the install-
ation regulations.
1.
Identify the phase and neutral conductors in the
socket.
The appliance may be damaged if it is not connec-
ted correctly.
2.
Connect the hob in accordance with the connection
diagram.
See the rating plate for the voltage.
3.
Connect the wires of the mains power cable accord-
ing to the colour coding:
‒
Green/yellow = Protective conductor
‒
Blue = Neutral conductor
‒
Brown = Phase (external conductor)