CP050B 
Night Arm Station

Security System

Installer Reference Guide

EN

Security Systems

Summary of Contents for CP050B

Page 1: ...CP050B Night Arm Station Security System Installer Reference Guide EN Security Systems ...

Page 2: ...r a panic alarm both the PART 1 and PART 2 buttons need to be held down simultaneously for at least two seconds The system sirens and strobes will activate and can only be deactivated by entering a valid user code via the keypad A panic alarm can be activated at any time whether or not the system is already armed Operation Arming and Disarming in PART Mode 1 and 2 With the system in the disarmed s...

Page 3: ... Arm or Disarm Part Mode 2 Press both buttons together for 2 seconds to trigger a Panic Alarm Once an alarm has been triggered you will need to enter a valid code from a keypad to cancel the alarm Status Indicators Press Button to Arm or Disarm Part Mode 1 Figure 1 CP050B Buttons and Indicators CP050B Front Panel Layout ...

Page 4: ...ayed on the status indicators Indicator Brightness The indicator brightness can be adjusted to suit the environment or personal preference To adjust press and hold down the PART 1 button for 2 seconds Both the indicators will come on indicating that the change mode is active Now press the PART 1 key repeatedly to reduce the brightness or the PART 2 key repeatedly to increase the bright ness Once t...

Page 5: ...list of valid module addresses and the corresponding mappings for each module Address Configuration Switch Number SW1 SW2 SW3 Night Arm Station Number Address 1 OFF OFF OFF 1 Address 2 ON OFF OFF 2 Address 3 OFF ON OFF 3 Address 4 ON ON OFF 4 Address 5 OFF OFF ON 5 Address 6 ON OFF ON 6 Address 7 OFF ON ON 7 Address 8 ON ON ON 8 Up to 8 x CP050B can be installed on the Solution 16i and Solution 14...

Page 6: ...system LAN See module connection specification below for more detail Programming Each CP050B is treated by the panel as if it were a standard keypad from the point of view of programming options This means that to change parameters for a Night Arm Station which is configured for address 3 you would need to select Keypad 3 under the devices menu and change the required parameters In a multi area sy...

Page 7: ...le Connection RS485 LAN Max total LAN length using multi strand security cable 300m Max total LAN length using 2 pair twisted shielded data cable Belden 8723 1200m See the control panel manual for full wiring instructions Operating Environment 0 to 55 C RH 5 to 85 at 30 C non condensing Fixing Method The CP050B can be directly installed onto a cavity or plaster wall using appropriate fixings or on...

Page 8: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2012 Bosch Security Systems CM050BIRG Issue FTR1 1 ...