![Bosch CC488 Quick Reference Manual Download Page 19](http://html.mh-extra.com/html/bosch/cc488/cc488_quick-reference-manual_39281019.webp)
CC488 |
Quick Reference Guide | 2.0 Programming Parameters
EN
| 19
Bosch Security Systems | 6/04 | 4998152446B
2.14.14
Speaker Beep Volume
Location
435
Default
13
0
15
No Beeps
Loudest Beeps
2.15 Options
Programming
2.15.1
System Options 1
Location
436
1
Bosch Security Systems smart lockout allowed
2
Horn speaker monitor
4
Strobe indication for radio arm/disarm
8
Assign button 4 on transmitter to operate STAY Mode 1
2.15.2
System Options 2
Location
437
Default
0
1
Codepad panic to be silent
2
Codepad fire to be silent
4
Codepad medical to be silent
8
Access denied (code retries) to be silent
2.15.3
System Options 3
Location
438
1
AC fail after 1 hr. (Disabled = after 2 min.)
2
Ignore AC fail
4
Pulse count handover allowed
8
Handover delay to be sequential
2.15.4
System Options 4
Location
439
Default
0
1
Panel to power up disarmed (if power reset)
2
Arm/disarm tracking on power up
4
Internal crystal to keep time
8
Radio keyswitch interface, night arm station, or RE005
installed
2.15.5
Consumer Options 1
Location
440
Default
0
1
Test reports only when armed
2
Test report after siren reset
4
Auto arm in STAY Mode 1
8
STAY indicator to display day alarm status
2.15.6
Consumer Options 2
Location
441
1
Codepad displays extinguish after 60 sec.
2
Single button arming allowed (AWAY/STAY Modes 1 and
2)
4
Single button disarming allowed (STAY Modes 1 and 2)
8
Alarm memory reset on disarm
2.15.7
Consumer Options 3
Location
442
1
Codepad fault beeps allowed
2
Use digit 3 for codepad duress alarm (instead of digit 9)
4
Alarms activate sirens and strobe outputs in STAY
Modes 1 and 2
8
Zone tamper alarms to be silent
2.15.8
Radio Input Options
Location
443
Default
0
1
RF Receiver (RF-3212/E) connected
2
Latching keyswitch input
3
Momentary keyswitch input
4 Reserved
2.15.9
Partitioning Options 1
Location
444
Default
0
1
First to Open/Last to Close reporting armed
2
Area 1 codepad connected to data terminal
4
Reset sirens from any area allowed
8
Master codepad to display AUX indicator when online
2.15.10
Partitioning Options 2
Location
445
Default
0
1 Lock area 1 to Receiver 1 and lock area 2 to Receiver 2
2 User codes allowed to arm/disarm both areas at same time
(Code [0][#])
4 Reserved
8 Reserved
2.16 Zone Allocations Programming
2.16.1
Zone Allocations for Area 1
Location
446 to 453
Location Default
Zone 1 LED – Area 1 Codepad
446
0
Zone 2 LED – Area 1 Codepad
447
0
Zone 3 LED – Area 1 Codepad
448
0
Zone 4 LED – Area 1 Codepad
449
0
Zone 5 LED – Area 1 Codepad
450
0
Zone 6 LED – Area 1 Codepad
451
0
Zone 7 LED – Area 1 Codepad
452
0
Zone 8 LED – Area 1 Codepad
453
0
2.16.2
Zone Allocations for Area 2
Location
454 to 461
Location Default
Zone 1 LED – Area 2 Codepad
454
0
Zone 2 LED – Area 2 Codepad
455
0
Zone 3 LED – Area 2 Codepad
456
0
Zone 4 LED – Area 2 Codepad
457
0
Zone 5 LED – Area 2 Codepad
458
0
Zone 6 LED – Area 2 Codepad
459
0
Zone 7 LED – Area 2 Codepad
460
0
Zone 8 LED – Area 2 Codepad
461
0