![Bosch CC488 Quick Reference Manual Download Page 17](http://html.mh-extra.com/html/bosch/cc488/cc488_quick-reference-manual_39281017.webp)
CC488 |
Quick Reference Guide | 2.0 Programming Parameters
EN
| 17
Bosch Security Systems | 6/04 | 4998152446B
2.13.2 Event
Codes
Event
Code
Description
0
0
EDMSAT – satellite siren (output 1 only)
0 1 System
armed
0 2 System
disarmed
0
3
Armed in STAY mode
0
4
Armed in AWAY mode
0 5 Pre-arming
alert
0
6
Exit warning (all zones sealed) and entry warning
0 7 Exit
warning
0
8
Exit warning finished
0
9
Kiss-off after end of exit time
0 10 Reserved
0 11 Entry
warning
0
12
Entry warning and day alarm resetting
0
13
Exit warning and entry warning and day alarm
resetting
0
14
Day alarm resetting
0
15
Day alarm latching
1
0
Day alarm enabled
1
1
Telephone line fail
1 2 Kiss-off
received
1 3 Fuse
fail
1 4 AC
fail
1 5 Low
battery
1
6
Horn speaker fail
1
7
Sensor watch alarm
1
8
Codepad medical alarm
1
9
Codepad fire alarm
1
10
Codepad panic alarm
1
11
Codepad duress alarm
1
12
Access denied (code retries)
1 13 Reserved
1
14
Horn speaker (output 1 only)
1 15 Sirens
running
2 0 Strobe
2 1 Silent
alarm
2
2
Alarm in STAY Mode
2
3
Alarm in AWAY Mode
2 4 System
fault
2
5
Fire alarm (resetting)
2
6
Fire alarm (latching)
2
7
Fire alarm (verification)
2
8
Remote control 1
2
9
Remote control 2
2
10
Remote control 3
2
11
Radio control output 1
2
12
Radio control output 2
2
13
Radio control output 1 - not in AWAY Mode
2
14
Radio control output 2 - not in AWAY Mode
2
15
Communications fail after 3 attempts
2.13.2 Event Codes (continued)
Event
Code
Description
3 0 Communications
fail
3 1 Dialler
disabled
3
2
Dialler active (on-line)
3 3 Ring
detect
3
4
Codepad panic (multi-break) V1.05+
3
5
Mimic zone 1
3
6
Mimic zone 2
3
7
Mimic zone 3
3
8
Mimic zone 4
3
9
Mimic zone 5
3
10
Mimic zone 6
3
11
Mimic zone 7
3
12
Mimic zone 8
3 13 Reserved
3 14 Reserved
3 15 Reserved
4 0 Reserved
4 1 Reserved
4 2 Reserved
4 3 Reserved
4 4 Reserved
4 5 Chime
4
6
Zone not sealed
4
7
Zone not sealed after exit time
4 8 Reserved
4
9
AC mains cycle (60 Hz or 50 Hz)
4
10
Area 1 – zone unsealed (Solution 880 only)
4
11
Area 2 – zone unsealed (Solution 880 only)
4 12 Reserved
4 13 Reserved
4 14 Reserved
4 15 Reserved
5 0 Reserved
5 1 Reserved
5
2
Area 1 in alarm (Solution 880 only)
5
3
Area 2 in alarm (Solution 880 only)
5 4 Reserved
5 5 Reserved
5
6
Area 1 armed (Solution 880 only)
5
7
Area 2 armed (Solution 880 only)
5 8 Reserved
5 9 Reserved
5
10
Area 1 disarmed (Solution 880 only)
5
11
Area 2 disarmed (Solution 880 only)
5 12 Reserved
5 13 Reserved
5
14
Any areas armed (Solution 880 only)
5
15
Any areas disarmed (Solution 880 only)
6
0
Area 1 codepad data terminal (Solution 880 only)
6
1
Area 2 codepad data terminal (Solution 880 only)